SERVICING INSTRUCTIONS
ACCESS PANELS
Top panel is held by four screws at the corners.
Front panel is held by two screws at the bottom and a retaining
lip at the top.
TEMPERATURE ADJUSTMENT
With the “READY TO BREW” light
ON
, draw a cup of water from
the hot water faucet. Check the temperature of the water with a
thermometer of known accuracy.
If temperature adjustment is necessary, remove water bottle and
top panel.
Adjust thermostat by turning shaft; clockwise increases
temperature. 1/8 turn = approximately 10ºF.
Refer to Table 1 below for proper brewing temperature based on
altitude.
Upon completion, reinstall top panel.
CAUTION
Electric Shock
Hazard
Opening access panels on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel
NOTE:
Optimum brewing temperature
range is 195ºF to 205ºF (90ºC
to 96ºC).
IMPORTANT:
A mechanical thermostat will
maintain temperature within
±10ºF. To prevent boiling water
in the brewer, thermostat should
be adjusted to a maximum
temperature equal to the local
boiling temperature minus 10ºF.
Fig. 8 Access Panels
Table 1 Boiling Temperature by Altitude
ELEVATION (feet above seal level)
0
50
0
1,
00
0
1,
50
0
2,
00
0
2,
50
0
3,
00
0
3,
50
0
4,
00
0
4,
50
0
5,
00
0
5,
50
0
6,
00
0
6,
50
0
T
E
M
P
.
(º
F
)
195
200
205
210
190
IDEAL
BREWING
TEMPERATURE
MAXIMUM SAFE
TEMPERATURE
SETTING
BOILING
POINT OF
WATER