RESET HI-LIMIT
Allow brewer to cool. Remove front panel.
Press red button on hi-limit until it clicks and stays in.
Reassemble in reverse order. Test for function and proper
operation.
REPLACE CONTROLLER
Unplug power cord OFF.
Remove front panel. Remove timer faceplate. Use needle nose
pliers to disengage three barbed fittings holding controller to
bracket. Disconnect keypad ribbon cable (note position “1”),
temperature probe and power board cable.
Reassemble in reverse order. Set jumpers as described below.
Adjust controller as described on page 15 & 16.
SET CONTROLLER JUMPERS
Slide jumper over both pins of V1 to set VALVE TIME range at
60 - 180 seconds.
Remove jumper from V1 to set VALVE TIME range at 120 - 250
seconds.
REPLACE KEYPAD
Unplug power cord. Shut off water supply valve. Remove top
and front panels. Remove faucet.
Disconnect ribbon cable from controller. Pry faceplate/keypad
from body. Remove all adhesive residue.
Remove protective backing from adhesive on new keypad. Slide
ribbon cable into slot on body from the outside, then carefully
apply keypad to face of body.
Ribbon cable connects to P2 on controller. Note locator marking
“1” on connector and cable.
Reassemble in reverse order. Test new keypad for function and
proper operation.
SERVICING INSTRUCTIONS (continued)
18
Fig. 17 Controller Hook-Up
Fig. 18 Keypad Ribbon Cable
Hook-Up