background image

SERVICING INSTRUCTIONS (continued) 

IMPORTANT: 

 Water pressure 

must be between 20 p.s.i and 
90 p.s.i. flowing pressure.         
If water pressure exceeds this 
value, or if water pressure     
varies greatly, a pressure   
regulator must be installed in 
the water supply line.

 

 
 
IMPORTANT:  

Before setting 

assembly into tank, make sure 
tank lid gasket is properly 
seated on flange of lid.  
 
 
 
 

IMPORTANT:  

When replacing 

temperature probe, be sure a 
new seal washer is in place 
around the probe.  Tighten jamb 
lock nut only enough to ensure 
no water  leakage.  Excessive 
tightening is not necessary.  

 

 

 

 

 

IMPORTANT:  

When replacing 

heating element, also replace 
seal gaskets. 
 
 

16 

BREW TIME ADJUSTMENT  

 

The amount of water dispensed automatically during a brew cycle 
is controlled by the SOLENOID TIME dial of the controller.   

 
Place empty decanter under brew chamber.  Press BREW      
button.  Brewer should dispense one full decanter of water.  To 
adjust amount: 

 
Remove brew chamber and button plug.  On the controller, adjust 
SOLENOID TIME dial (BREW TIME);  clockwise increases time. 
Run several cycles to check amount of water delivered.  
 

DRIPOUT TIME ADJUSTMENT 

 
Water delivered to the brew chamber will take a while to drip 
through as coffee.  The time between the end of a brew and 
when a new brew can be initiated is controlled by the BREW  
SIGNAL TIMER.  Adjust the BREW SIGNAL TIMER dial on the 
controller to account for the dripout time.  Replace button plug. 

 
REMOVE TANK LID ASSEMBLY 

 
Unplug brewer or turn circuit breaker 

OFF

.  Turn 

OFF

 water   

supply.  Remove top panel.  Pull vent tube and inlet elbow out of 
basin pan. 

 
On automatic models, pull water inlet tube out of basin pan.     
Remove basin pan. 

 
On models with faucet, disconnect inlet pipe at faucet shut-off 
valve and outlet pipe at faucet. 

 
Disconnect all wiring from hi-limit and heating element.            
Disconnect temperature probe from controller. 

 
Loosen center screw on tank hold-down bracket.  Remove    
hold-down bracket by sliding short slotted end off of locking stud 
and lifting it off.  Remove cover assembly by lifting it straight up. 

 
Reassemble in reverse order. 
 

REPLACE TEMPERATURE PROBE 

 
Unplug brewer or turn circuit breaker 

OFF

.  Remove top panel. 

 
Loosen and free jam nut from pass-thru fitting securing            
temperature probe.   Disconnect temperature probe wiring      
connector from controller. 
Lift out probe, jamb nut and gasket. 

 
Reassemble in reverse order. 

 

REPLACE HEATING ELEMENT 

 
Remove tank lid assembly per above. 

 
Remove two hex nuts holding element to cover.  Pull element 
from mounting holes. 

 
Reassemble in reverse order. 

Fig. 14 Adjust BrewTime 
             and Dripout Time 

Summary of Contents for 1016BVM

Page 1: ...12821 M912 050210 cps 912 OWNERS MANUAL for E B C Electronic Brew Control COFFEE BREWERS MODEL 1016BVM Includes Installation Operation Use Care Servicing Instructions This instruction is for the excl...

Page 2: ...coffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHAN...

Page 3: ...This manual contains the information needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY...

Page 4: ...1016BVM FEATURES AND OPERATING CONTROLS 2 Fig 1 1016BVM Features and Operating Controls...

Page 5: ...nts This appliance is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must...

Page 6: ...sure an ample water supply Remember to flush the line prior to installing the saddle The brewer must be installed on a water line with average pressure between 20 PSI and 90 PSI If your water pressure...

Page 7: ...receptacle The water line must terminate in a 1 4 male flare fitting which will connect to the provided flex line See Figure 2 below In some areas local codes require a backflow preventer check valve...

Page 8: ...sounding 3 Be sure the brewer is OFF if necessary press ON OFF key until no LEDs are lit 4 Press BREW key three 3 times then press CANCEL key once BREW and HEAT indicators will flash while tank is fi...

Page 9: ...y energizes the solenoid valve allowing water from an external water supply to flow into the water tank The incoming water forces heated water out of the tank to perform the brew The solenoid uses a f...

Page 10: ...w cycle three beeps will sound NOTE To override Brew Waiting Mode press and hold the BREW key for 3 seconds while the BREW indicator is flashing Brew will begin regardless of water temperature To avoi...

Page 11: ...able Enable After Hours Feature To disable After Hours press the ON OFF key to turn the brewer OFF Press and hold the CANCEL key until two beeps sound and the HEAT indicator flashes twice This feature...

Page 12: ...sh coffee grounds Gently shake the brew chamber to level the bed of grounds Slide the brew chamber into place under the brew head B AUTOMATIC OPERATION BE sure HEAT light is not lit Place the appropri...

Page 13: ...ter and allow to air dry 7 Wash the brew chamber in a sink using warm water and a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry 8 Wipe warm...

Page 14: ...ed Thoroughly clean brew chamber Too much coffee or too fine a grind Use correct grind and amount of coffee Sprays water from brew head Spray gasket improperly installed Check reinstall gasket on INSI...

Page 15: ...unplug brewer and replace temp probe Check power board and heating element Brewer will go into error mode 4 minutes after energizing the heating element if insufficient heat rise is detected The heati...

Page 16: ...ng Top panel is held by two screws at the front and a retaining lip at the rear FRONT PANEL Remove upper front panel to access controller power board and solenoid Upper front panel is held by two scre...

Page 17: ...ewing temperature based on altitude Upon completion remove thermometer and reinstall the plug or vent tube Fig 13 Checking and Adjusting Brew Temperature CAUTION Electric Shock Hazard These procedures...

Page 18: ...as coffee The time between the end of a brew and when a new brew can be initiated is controlled by the BREW SIGNAL TIMER Adjust the BREW SIGNAL TIMER dial on the controller to account for the dripout...

Page 19: ...et coil also replace seal gaskets Remove tank lid assembly per above Remove two hex nuts hot water coil to cover Pull coil from mounting holes REPAIR HOT WATER FAUCET Remove top panel and turn faucet...

Page 20: ...ERS Slide jumper over both pins of V1 to set VALVE TIME range at 60 180 seconds Remove jumper from V1 to set VALVE TIME range at 120 250 seconds REPLACE KEYPAD Unplug power cord Shut off water supply...

Page 21: ...n pull tank from cabinet to allow access to board Note position of wires at power board then remove wires Suggestion Marking these wires is highly recommended to ease reinstallation Remove screws hold...

Page 22: ...sh Large Sink or other appropriate work area 1 Unplug power cord Turn off the water shut off valve and disconnect the water supply line from the brewer inlet fitting 2 Remove the tank lid assembly as...

Page 23: ...nternal components are dry then reinstall the top panel 10 Reconnect brewer to electrical supply and reconnect water supply 11 Install the brew chamber without filter paper or grounds Run at least thr...

Page 24: ...EXPLODED VIEW PARTS LIST continued 22...

Page 25: ...6 8552 18 TERMINAL BLOCK 1 37 8716 1 ELEMENT TANK 240V 3500W 1 38 8552 50 THERMOSTAT HI LIMIT RESET 1 39 8706 65 SCREW PAN PHL 6 23x7 8 SS 2 40 83319 PLUG TANK LID 298 DIA 41 8706 76 PLUG BUTTON 1 1 8...

Page 26: ...Cup 12d Spring 12h Stem 12j Pin 12k Bonnet 82682 Retainer Clip item 12b 84804 Aerator Replacement Kit Includes 12e O Ring 12f Aerator Disk 12g Aerator Cap 84870 Aerator Repair Kit Includes 12e O Ring...

Page 27: ...1016BVM WIRING DIAGRAM 25...

Page 28: ...tries Inc Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries p...

Reviews: