OPERATION (continued) 

ELECTRONIC FEATURES 

 

Energizing the Brewer 

 

When electric power is applied to the unit, all the lights will flash four 
times and four beeps will sound.  The unit will be 

OFF

 
Press the ON/OFF key.  Four beeps will sound and all lights will flash 
once.  The POWER indicator will remain 

ON

.  If the water temperature 

is more than 10ºF below the setpoint, the HEAT indicator will glow until 
water temperature reaches setpoint. 

 
Press the ON/OFF key again to turn the brewer 

OFF

.  Three beeps will 

sound, the tank heater and all warmers will be switched off, and all   
indicator lights will go out.  
 

Brew Settings 

 
See pages 17 & 18 for setting Brew Time and Temperature. 
 

ABS™ (Automatic Brew Start) 

 
Start a brew by pressing BREW.  A single beep will sound. The system 
will verify that the water in the tank is at the proper temperature.  If it is, 
brew will start immediately.  Otherwise, the BREW indicator will flash 
(Brew Waiting Mode) until the water reaches setpoint temperature, 
then the indicator will glow and brew will commence.  If the main 
warmer is off, it will be energized automatically. 

 
At the conclusion of the brew cycle, three beeps will sound. 

 

NOTE:  

To override Brew Waiting Mode, press and hold the BREW 

key for 3 seconds while the BREW indicator is flashing.  Brew will     
begin regardless of water temperature.  To avoid under-temperature 
brews, this feature should only be used when setting brew volumes. 
 

NOTE:  

Brew Waiting Mode (BREW indicator flashing) prevents      

multiple, unattended brews.  While the BREW indicator is on or      
flashing, any additional strokes of the BREW key will be ignored (there 
will be a beep each time the key is pressed, however).  Another brew 
cannot be initiated until the previous brew is complete. 

 
The Brew Waiting Time, also called Dripout Time, (interval between 
when the brew is initiated and the audible signal sounds at the end     
of the brew) may be adjusted between 2 and 8 minutes at the Brew 
Signal Timer dial on the controller.  See page 18. 
 

Brew Cancel 

 
To cancel a brew in progress or a brew in waiting, press the CANCEL 
key.  Two beeps will sound and the BREW indicator will go out. 

 

NOTE:  

If a brew in progress is cancelled, coffee will continue to flow 

until all water delivered has dripped through the brew chamber. 

IMPORTANT: 

DO NOT energize this 
brewer until the water tank 
has been filled.  Dry firing 
will damage heating      
elements.  See page 6. 

 
 
 
 
 
 
 
 
 
 
 
 

Fig. 6       Turning Brewer 
                

ON

 or 

OFF

 

 
 

 
 
 
 
 
 
 
 
 
 

Fig. 7       Initiate a Brew 

 

 
 
 
 
 
 
 
 
 
 
 

Fig 8.       Brew Cancel 

Summary of Contents for 1016BVM

Page 1: ...12821 M912 050210 cps 912 OWNERS MANUAL for E B C Electronic Brew Control COFFEE BREWERS MODEL 1016BVM Includes Installation Operation Use Care Servicing Instructions This instruction is for the excl...

Page 2: ...coffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHAN...

Page 3: ...This manual contains the information needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY...

Page 4: ...1016BVM FEATURES AND OPERATING CONTROLS 2 Fig 1 1016BVM Features and Operating Controls...

Page 5: ...nts This appliance is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must...

Page 6: ...sure an ample water supply Remember to flush the line prior to installing the saddle The brewer must be installed on a water line with average pressure between 20 PSI and 90 PSI If your water pressure...

Page 7: ...receptacle The water line must terminate in a 1 4 male flare fitting which will connect to the provided flex line See Figure 2 below In some areas local codes require a backflow preventer check valve...

Page 8: ...sounding 3 Be sure the brewer is OFF if necessary press ON OFF key until no LEDs are lit 4 Press BREW key three 3 times then press CANCEL key once BREW and HEAT indicators will flash while tank is fi...

Page 9: ...y energizes the solenoid valve allowing water from an external water supply to flow into the water tank The incoming water forces heated water out of the tank to perform the brew The solenoid uses a f...

Page 10: ...w cycle three beeps will sound NOTE To override Brew Waiting Mode press and hold the BREW key for 3 seconds while the BREW indicator is flashing Brew will begin regardless of water temperature To avoi...

Page 11: ...able Enable After Hours Feature To disable After Hours press the ON OFF key to turn the brewer OFF Press and hold the CANCEL key until two beeps sound and the HEAT indicator flashes twice This feature...

Page 12: ...sh coffee grounds Gently shake the brew chamber to level the bed of grounds Slide the brew chamber into place under the brew head B AUTOMATIC OPERATION BE sure HEAT light is not lit Place the appropri...

Page 13: ...ter and allow to air dry 7 Wash the brew chamber in a sink using warm water and a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry 8 Wipe warm...

Page 14: ...ed Thoroughly clean brew chamber Too much coffee or too fine a grind Use correct grind and amount of coffee Sprays water from brew head Spray gasket improperly installed Check reinstall gasket on INSI...

Page 15: ...unplug brewer and replace temp probe Check power board and heating element Brewer will go into error mode 4 minutes after energizing the heating element if insufficient heat rise is detected The heati...

Page 16: ...ng Top panel is held by two screws at the front and a retaining lip at the rear FRONT PANEL Remove upper front panel to access controller power board and solenoid Upper front panel is held by two scre...

Page 17: ...ewing temperature based on altitude Upon completion remove thermometer and reinstall the plug or vent tube Fig 13 Checking and Adjusting Brew Temperature CAUTION Electric Shock Hazard These procedures...

Page 18: ...as coffee The time between the end of a brew and when a new brew can be initiated is controlled by the BREW SIGNAL TIMER Adjust the BREW SIGNAL TIMER dial on the controller to account for the dripout...

Page 19: ...et coil also replace seal gaskets Remove tank lid assembly per above Remove two hex nuts hot water coil to cover Pull coil from mounting holes REPAIR HOT WATER FAUCET Remove top panel and turn faucet...

Page 20: ...ERS Slide jumper over both pins of V1 to set VALVE TIME range at 60 180 seconds Remove jumper from V1 to set VALVE TIME range at 120 250 seconds REPLACE KEYPAD Unplug power cord Shut off water supply...

Page 21: ...n pull tank from cabinet to allow access to board Note position of wires at power board then remove wires Suggestion Marking these wires is highly recommended to ease reinstallation Remove screws hold...

Page 22: ...sh Large Sink or other appropriate work area 1 Unplug power cord Turn off the water shut off valve and disconnect the water supply line from the brewer inlet fitting 2 Remove the tank lid assembly as...

Page 23: ...nternal components are dry then reinstall the top panel 10 Reconnect brewer to electrical supply and reconnect water supply 11 Install the brew chamber without filter paper or grounds Run at least thr...

Page 24: ...EXPLODED VIEW PARTS LIST continued 22...

Page 25: ...6 8552 18 TERMINAL BLOCK 1 37 8716 1 ELEMENT TANK 240V 3500W 1 38 8552 50 THERMOSTAT HI LIMIT RESET 1 39 8706 65 SCREW PAN PHL 6 23x7 8 SS 2 40 83319 PLUG TANK LID 298 DIA 41 8706 76 PLUG BUTTON 1 1 8...

Page 26: ...Cup 12d Spring 12h Stem 12j Pin 12k Bonnet 82682 Retainer Clip item 12b 84804 Aerator Replacement Kit Includes 12e O Ring 12f Aerator Disk 12g Aerator Cap 84870 Aerator Repair Kit Includes 12e O Ring...

Page 27: ...1016BVM WIRING DIAGRAM 25...

Page 28: ...tries Inc Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries p...

Reviews: