2.3 Product Specification
Section 3 – Installation & Power-up
3.1 Unpacking
You will find the following items in the box:
•
BT-HE-DASHBOARD headend controller (QTY=1)
•
External 12 volt power supply (QTY=1)
3.2 Before You Begin
Before you begin, please note that there should be only one (1) DHCP server in the network (refer to Diagram 1 in Section 2).
Verify firmware version(s) as per table below. If an AQT8 is being used, then user MUST first change from “Static” to “Static
until DHCP”.
Product Models: Compatibility, Firmware Requirements, and IP Setting Information
Product
IP Default
Setting
Firmware
Version
During boot up/ power up of unit
Static until DHCP
8C
(w/Opt 2)
DHCP
3.0.44
or higher
DHCP requests last forever if no DHCP server
is available, but defaults to Static IP (you can
get to unit with its default static IP address)
DHCP requests last forever if no DHCP server
is available, but defaults to Static IP (you can
get to unit with its default static IP address)
8C DIN
(w/Opt 2)
DHCP
4.0.46
or higher
Same as 8C
Same as 8C
AQT8
QAM/IP &
IP Models
Static
1.0.10P17
or higher
Prior to BT-HE-DASHBOARD installation, IP
mode MUST be changed to Static until DHCP.
(See Product Manual)
After required mode change, same as 8C
The BT-HE-Dashboard requires an external DHCP server. (Example: see Diagram 1 on page 7)
All units MUST be updated to minimum required firmware version (shown in the table above)
BEFORE connecting them to the BT-HE-DASHBOARD.
Alarms/Monitoring/Control
Local Monitoring:
Local Control:
1x Status LED
1x Power LED
1x IP Reset button
Remote Monitoring/
Control:
1x RJ45
(10/100Base-T)
GUI-based menu via web browser
General
Dimensions:
(W x D x H)
6.7” x 1.25” x 5.125”
(170 mm x 32 mm x 130 mm)
Power Supply:
Power Dissipation:
12 VDC @ 150 mA from external
power supply
(included)
~2 W
(max)
Weight:
~2.0 lbs
(0.9 kg)
Operating Temperature:
Storage Temperature:
32 to 122 ˚F
(0 to 50 ˚C)
-13 to 158 ˚F
(-25 to 70 ˚C)
Operating Humidity:
Storage Humidity:
0 to 95% RH @ 35 ˚C max,
non-condensing
0 to 95% RH @ 35 ˚C max,
non-condensing