6 BT-HE-DASHBOARD
User Manual
LEFT SIDE PANEL:
POWER LED:
LED is Green
= power is detected when 12VDC is applied to unit.
LED is Off
= indicates (i) AC power is not connected, or (ii) AC power is connected but the power supply is defective.
The unit must be sent to Blonder Tongue for repair for condition (ii).
IP RESET:
When pushed and held for >2 seconds, the Ethernet port IP address login credentials will be enabled to the
factory defaults. The power LED will blink Green while in this state. Reboot the unit to return to normal operation.
Factory Defaults:
IP Address
= 172.16.70.1 (Subnet Mask: 255.255.255.0)
Username
= Admin (case-sensitive)
Password
= pass (case-sensitive)
NOTE:
The user-defined IP address, login and password will still be present within the encoder settings.
STATUS LED:
LED is on (green) under normal operating conditions. If IP reset button is pressed for a few seconds, the
LED will blink.
RIGHT SIDE PANEL:
ETHERNET:
RJ45 connector for 10/100Base-T Ethernet interface. (Factory Default: 172.16.70.1)
INPUT POWER:
12 VDC @ 150 mA from external power supply.
1
2
2
4
5
Description:
Unit left and right side panel connectors and indicators:
2.2 Product Application & Description (Continued)
1
2
3
4