Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 25 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PKP-2400-LI_CANOpen_UM_REV1.1
21.
Object 100Ah: Manufacturer Firmware Revision
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
0Ah
CAN Object 100Ah
Byte 2
10h
Byte 3, 7
00h
Not used
1
°
additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
60h
Read Device Register second byte
Byte 1, 7
00h
Not used
2
°
additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
70h
Read Device Register third byte
Byte 1, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 0A 10 00 00 00 00 00
Keypad reply
595
Std
41 0A 10 00 0A 00 00 00
To Keypad
615
Std
60 00 00 00 00 00 00 00
Keypad reply
595
Std
00 52 65 76 20 31 2E 30 Rev 1.0
To Keypad
615
Std
70 00 00 00 00 00 00 00
Keypad reply
595
Std
19 00 52 00 00 00 00 00 R
Manufacturer firmware revision: Rev 1.0R. The first byte of the last data message replied is 19h.
22.
Object 100Bh: Model ID
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
0Bh
CAN Object 100Bh
Byte 2
10h
Byte 3, 7
00h
Not used
1
°
additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
60h
Read Device Register second byte
Byte 1, 7
00h
Not used
2
°
additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
70h
Read Device Register third byte
Byte 1, 7
00h
Not used
Example: