3.
Default settings
Setting
Default status or level
How to change
Baud Rate
125 kbit/s
Object 6500h Command 11h
CANopen Node ID
15h
Object 6500h Command 70h
Device active on
startup
Not active
Object 6500h Command 10h
Key Brightness
3Fh (Maximum Brightness)
Object 6500h Command 02h
Backlight Brightness
00h (OFF)
Object 6500h Command 03h
Backlight Color
Amber
Object 6500h Command 7Dh
Startup LED Light
Show
Complete LED Sequence
Object 6500h Command 50h
Periodic Message
Transmission
Disable
Object 6500h Command 12h
DEMO mode
Disable
Object 6500h Command 7Ah
Heartbeat Message
Disable
Object 1017h
Boot-up service
Active
Object 6500h Command 13h
NMT MESSAGES
The Network Management messages follow a master-slave structure. Through NMT
services, CANopen devices are initialized, started, reset or stopped. All CANopen devices
are regarded as NMT slaves.
NMT messages have CAN-ID always equal to 00h.
4.
Start CANopen node (keypad activation message)
Identifier
00h
Byte 0
01h
Start CANopen node
Byte 1
XXh
Keypad CAN ID
00h: start all the keypads
15h: start the keypad with CAN ID =
15h.
Byte 2, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
To Keypad
0
Std
01 15
5.
Enter pre-operational
Identifier
00h
Byte 0
80h
Enter pre-operational
Byte 1
XXh
Keypad CAN ID
00h: enter all the keypads
15h: enter the keypad with CAN ID =
15h.
Byte 2, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
To Keypad
0
Std
80 15