26.
Object 1600h: Output Descriptions
Receives asynchronously digital outputs mapping
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
00h
CAN Object 1600h
Byte 2
16h
Byte 3
XXh
00h: Number of mapped objects
01h: Set LED outputs
02h: Set LED blink
Byte 4,7
00h
Not used
Example:
Direction
Identifier Format
Message
Data
To Keypad
615
Std
40 00 16 00 00 00 00 00
Keypad reply
595
Std
4F 00 16 00 02 00 00 00 2
To Keypad
615
Std
40 00 16 01 00 00 00 00
Keypad reply
595
Std
43 00 16 01 20 00 01 60 6001 00 20h
To Keypad
615
Std
40 00 16 02 00 00 00 00
Keypad reply
595
Std
43 00 16 02 20 00 02 60 6002 00 20h
Output descriptions:
Number of mapped objects:2,
Sets LED output: Object 6001h, Sub index 00h, Length 20h;
Sets LED blink: Object 6002h, Sub index 00h, Length 20h.