G:\InDATA\manuals\OM-1607 E V1.02
November 19, 2012
Page 29
TORINO II Insert1607
FUEL CONVERSION
WARNING:
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible for the
proper installation of this kit. The installation is not proper and complete until the operation of the converted
appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
CONVERSION KIT CONTENTS
This conversion kit contains the following parts:
1. Z0712 (LPG)> # 53 and LPG Stepper motor kit.
2. Z0714 (NG)> # 38 and NG Stepper motor kit.
3. Conversion Kit labels.
To convert from NG to LPG or reverse, follow the next steps:
1. Replace orifices, see “BURNER TRAY REMOVAL AND INSTALLATION” on page 31 for Burner tray
removal & installation.
2. Replace stepper motor (see next page).
3. Convert pilot fuel (see instructions below).
How to convert Pilot fuel:
1. Use a 7/16” wrench to loosen the pilot hood.
2. Push the little tab in and the little tab with hole should pop out. The hole stamp tab (LP) out is used for
Propane. The stamped tab (NA) out is for Natural Gas.
3. Re-tighten the pilot hood.
Fill out the fuel conversion label on the appliance (inside side doors)
See “INSTALLATION INSTRUCTIONS cont.” on page 15 for proper pilot and burner flame pictorials.
All valves have been pre-set and certified for installation at elevations from 0 – 4500 feet (1 – 1372m) above sea
level.
HIGH ELEVATIONS
When installing this unit at higher elevations, it is necessary to decrease the input rating by replacing the existing
burner orifice with a smaller size for installations over 4500 feet (1370 m). The appliances input should be
reduced 4% for each additional 1000 feet (305 m) above sea level. For the USA, de-rate the unit from sea level
according to the gas installation code.
Altitude
NG
LPG
0 – 4,500 ft (0 – 1372 m)
36
52
4,500 – 6,500 ft (1372 – 1981 m)
38
53