8) Slide the completed unit into its final location.
9)
Place the Convection deck on the top of the firebox and fasten to the shroud top using the 2 screws provided (see
Fig. 7).
10) Install the catalytic thermometer by inserting the probe into the hole on the top of the stove.
11) Plug the fan into a nearby AC plug outlet. NEVER run the AC fan cord under the fireplace insert.
INSTALLATION INTO FACTORY BUILT FIREPLACES
In addition to the general instructions presented throughout the manual you must ensure the following steps are also
taken when installing this insert into a factory built fireplace.
1) The factory built fireplace must be listed to
UL 127
or
ULC S620,
and is installed and maintained to comply with
all local building codes.
2) All clearances to combustibles must be maintained as shown on the label.
3) The installation must include a full-length liner, which is attached from the insert to the chimney cap. In Canada,
the factory built chimney must be lined from the outlet of the insert to the top of the chimney using a stainless
steel liner that meets UL 1777 or ULC S635.
4) Air passage to the chimney cavity of the fireplace must be prevented by sealing the damper area around the
chimney liner, or sealing the fireplace front.
5) The airflow in and around the fireplace must not be altered by the installation of the insert (i.e.: no louvers or
cooling air outlet ports should be blocked).
6) No alterations of the factory built fireplaces are allowed except as follows:
a) External trim which does not affect the operation of the fireplace may be removed providing it can be stored
on or within the fireplace for reassembly if the insert is removed.
b) The chimney damper may be removed to install the chimney liner.
7) Circulating air chambers, in a steel fireplace liner or metal heat circulator, should not be blocked.
8) The ability to remove the insert and clean the chimney flue must be provided.
9) If the insert protrudes from the front of the fireplace it must be supported and all clearance requirements must be
met.
10) A permanent metal warning label must be attached to the back of the fireplace stating that once the insert is
removed the fireplace must be restored to its original condition .
Figure 7
Assembly - General