How to convert CLARITY 26 FS IPI Pilot fuel:
1. Remove the spring clamped hood from pilot and
set aside (
Fig. 5
).
2. Unscrew regulator from pilot using a 4 mm allen
key (
Fig. 6
), then screw in the new regulator.
(
Fig. 7
)
3. Align the pilot hood with the tab and re-attach the
pilot hood to the spring clamp.
4. Fill out the fuel conversion label and affi x between
the two labels on the control panel door.
All valves have been pre-set and certifi ed for
installation at elevations from 0 – 4500 feet (1 –
1372m) above sea level.
HIGH ELEVATIONS
When installing this unit at higher elevations,
it is necessary to decrease the input rating by
replacing the existing burner orifi ce with a smaller
size for installations over 4500 feet (1370 m). The
appliances input should be reduced 4% for each
additional 1000 feet (305 m) above sea level. For the
USA, de-rate the unit from sea level according to the
gas installation code.