11. SPECIFICATION
DC Injection Current(mA)
Grid Frequency Range
Max.Efficiency
Euro Efficiency
>99%
MPPT Efficiency
Model
Input Side
Output Side
Efficiency
General Data
Max.DC Power(kW)
Max.DC Input Voltage(V)
Start-up DC Input Voltage(V)
MPPT Operating Range(V)
Max.DC Input Current(A)
Number of MPPT/Strings per MPPT
Rated Output Power(kW)
Max.Active Power(kW)
Rated AC Grid Voltage(V)
AC Grid Voltage Range(V)
Rated Grid Frequency(Hz)
Operating Phase
Rated AC Grid Output Current(A)
Max.AC Output Current(A)
Output Power Factor
<0.5%
47-52 or 57-62
(
optional
)
98.5%
97.5%
250
1000
200~850
BPT-V03-12
15.6
12
13.2
17.4
19.1
220/380, 230/400
277 ~ 460Vac (this may vary with grid standards)
50/60(Optional)
Three phase
BPT-V03-15
19.5
11+22
2/1+2
15
16.5
21.8
23.9
0.8 leading~0.8 lagging
<3%
Grid Current THD
330×430×193.5
Transformerless
Size(mm, W×H×D)
17
Weight(kg)
Topology
<1W(Night)
Internal consumption
-25 ~ 65
℃
Operating temperature
Ingress protection
IP65
<45dB
Smart cooling
Max. operation altitude
Cooling Concept
Noise Emission(Typical)
2000m
>20 Years
Designed Lifetime
MC-4 mateable
DC Connection
IP65 rated plug
AC Connection
LCD1602
Display
RS485/RS232/Wifi/LAN
Interface
General Data
EN50549-1, IEC61727, IEC62116, IEC60068, IEC61683, VDE0126-1-1,
RD1699, UNE206006IN, UNE206007-1 IN, UNE217001IN
Grid Connection Standard
Operation surrounding humidity
0~100%
IEC62109-1/-2, IEC61000-6-1, IEC61000-6-3, IEC61000-3-11,
IEC61000-3-12
Stafty EMC / Standard
Hymon
Fotowoltaika Sp z o.o.
ul. Dojazd 16A 33-100 Tarnów
Wyłączny dystrybutor nowoczesnych systemów
www.
hymon
.pl
44