GRID-TIED PV STRING INVERTER

USER MANUAL

BPT-V03-15

BPT-V03-12

Summary of Contents for BPT-V03-12

Page 1: ...Czerp korzy ci Hymon Fotowoltaika Sp z o o ul Dojazd 16A 33 100 Tarn w Wy czny dystrybutor nowoczesnych system w GRID TIED PV STRING INVERTER USER MANUAL BPT V03 15 BPT V03 12...

Page 2: ...NAL CONNECTION 5 2 AC INPUT TERMINAL CONNECTION 5 3 THE CONNECTION OF THE GROUND LINE 5 4 MAX OVER CURRENT PROTECTION DEVICE 5 5 INVERTER MONITORING CONNECTION 5 7 CONFIGURATION OF DATALOGGER 6 STARTU...

Page 3: ...ted documents before performing any operation on the inverter Documents must be stored carefully and be available at all times Contents may be periodically updated or revised due to product developmen...

Page 4: ...s steel screws M4 12 x4 Grid tied PV String Inverter x1 DC power connectors including Inserted spring x3 Stainless steel anti collision bolt M6 80 x4 AC power connectors x1 User manual User manual x1...

Page 5: ...could result in some damage or the destruction of the inverter Warning Warning symbol indicates important safety instructions which if not correctly followed could result in serious injury or death Sh...

Page 6: ...east 5 mins to avoid getting shocked 3 Local temperature of the inverter may exceed 80 while under operating Do not touch to avoid getting injured 4 All electrical installation must be in accord with...

Page 7: ...e 3 1 for details Explanation Inverter detects DC input Low DC input voltage Grid Connected Grid Unavailable Under normal operating Stop operating Detected faults or report faults Under normal operati...

Page 8: ...ss to modify the adjustable settings the Esc and Enter keys The two line Liquid Crystal Display LCD is located on the front panel of the Inverter which shows the following information Inverter operati...

Page 9: ...l in small closed spaces where air can not circulate freely To avoid overheating always make sure the flow of air around the inverter is not blocked Exposure to direct sunlight will increase the opera...

Page 10: ...ess than expected output power If install more than one inverter must leave at least 500mm gap between each inverter And each inverter must be at least 500mm above and below And must install the inver...

Page 11: ...NSTALLATION The inverter is designed according to the wall mounted type installation please use the wall mounted the brick wall of the expansion bolt when installing 500mm 500mm AC DC Normal Alarm ESC...

Page 12: ...nk to the hanging plate to ensure that the inverter will not move PROCEDURE SHOWS BELOW 1 Locate on the appropriate wall according to the bolt position on the mounting bracket then mark the hole On th...

Page 13: ...ecting inverter please make sure the PV array open circuit voltage is within the 1000V of the inverter Safety Hint Before connection please make sure the polarity of the output voltage of PV array mat...

Page 14: ...to the top part of the connector as shown in picture 5 5 Pic 5 3 Disassemble the connector cap nut 7mm 7mm W Pic 5 5 connector with cap nut screwed on d Finally insert the DC connector into the posit...

Page 15: ...10 20 25mm 30A 400V Warning Prohibit using a single circuit breaker for multiple inverters prohibit the connection of load between inverter circuit breakers The AC output connector is divided into th...

Page 16: ...n turn and insert each cable core into the corresponding jack and set each screw The connection hole of AC connection terminal labeling is shown in Picture 5 9 Step 5 Set the sleeve and sealing ring i...

Page 17: ...installation of the shell ground wire is shown as picture 5 11 Warning Inverter has built in leakage current detection circuit If an external leakage current protection device is connected its operati...

Page 18: ...figuration of datalogger please refer to illustrations of the datalogger 5 7 CONFIGURATION OF DATALOGGER Pic 5 13 Datalogger installation diagram DC SWITCH RS485 RS232 485 limiter ON OFF When the inve...

Page 19: ...ny conditions b Each input of the inverter better use the same type of photovoltaic module in series c Total output power of pv shall not exceed the maximum input power of inverter each photovoltaic m...

Page 20: ...ction The SUN limiter shows as Pic 7 1 You can see corresponding line mark next to the green interface The green terminals on the left are the interface of three phase AC line L1 L2 L3 and N Line N an...

Page 21: ...ose one wire from the bottom of the three phase DC switch any phase of U V W to connect with L1 terminal then tighten the line with a screwdriver 2 Connect SUN limiter to clamp senor Clamp senor can m...

Page 22: ...of terminal and connect the red line to number 1 and black line to number 2 shown as the picture After that connect the terminal to the interface of the SUN limiter The other side of the line should b...

Page 23: ...limit function and press the button enter At this time you can turn on or turn off the limit function by choosing up down button please press enter button to confirm when setting done 5 Move the curs...

Page 24: ...power of the grid without backflow Pic 7 10 Limiter function turn on 7 4 1 ZERO EXPORT FUNCTION VIA ENERGY METER When you are reading this we believe that you have completed the connection according...

Page 25: ...id RS 485 RS 485 B RS 485 A B A G 5 6 7 8 1 2 3 4 Pic 7 12 Connection diagram of Eastron meter Solar Panel array Inverter meter AC Breaker Grid RS485 Communication Family load E E E E E VCC_5V 485_B 4...

Page 26: ...IESC Eastron Pic 7 13 Connection diagram of Eastron meter Solar Panel array Inverter meter AC Breaker Grid RS485 Communication E E E d d d t t t L1 L2 L3 N VCC_5V 485_B 485_A 485_A 485_B GND GND RS 48...

Page 27: ...666 Warning Ensuring grid input cables connect 1 4 7 10 port of energy meter and inverter AC output cables connect 3 6 9 10 port of energy meter when connecting 1 7 4 10 25 24 3 9 6 10 Pic 7 16 Connec...

Page 28: ...ter to save the settings and exit the running parameters page otherwise the settings are invalid 6 If set up successfully you can return to the menu interface and display the LCD to home page by press...

Page 29: ...n Firstly go to the solarman platform https pro solarmanpv com this link is for solarman distributor account or https home solarmanpv com this link is for solarman end user account plant home page and...

Page 30: ...33 100 Tarn w Wy czny dystrybutor nowoczesnych system w www hymon pl 30 And then choose your system type as Self consumption Secondly go to plant page if it shows the PV power load power and grid powe...

Page 31: ...AL OPERATION During normal operation the LCD shows the current status of the inverter including the current power total generation a bar chart of power operation and inverter ID etc Press the Up key a...

Page 32: ...ent AC voltage AC current and inverter temperature Pic 8 3 PV input voltage and current information Pic 8 4 Load power Pic 8 5 Grid voltage and current information Pic 8 6 Grid voltage and frequency P...

Page 33: ...2 2 FAULT RECORD Pic 8 11 Load consumption LoadEp Daily consumption Total Total energy consumption Pic 8 12 PV generation E Day Daily generation E Total Total generation Pic 8 13 Device information 8...

Page 34: ...o to standby mode and then will go to self test program again If it passed the self test it will start to work again Pic 8 15 ON OFF setting 8 2 3 ON OFF SETTING There are five submenus in the setup S...

Page 35: ...ime set Pic 8 23 Reset to factory setting Pic 8 24 Password 8 4 RUNNING PARAM SET Note Password required only for access authorized engineer Un authorized access may avoid the warranty The initial pas...

Page 36: ...s Island Anti islanding protection Meter Energy meter If inverter will connect meter then set here to ON Pic 8 25 8 4 1 ACTIVEP SET Pic 8 26 Pic 8 27 Pic 8 28 Limiter If inverter will connect SUN limi...

Page 37: ...y requirements so customers don t need to reset it The password is same as 8 4 Running param 8 5 PROTECT PARAM Pic 8 31 Password Note Engineer only Hymon Fotowoltaika Sp z o o ul Dojazd 16A 33 100 Tar...

Page 38: ...Hymon Fotowoltaika Sp z o o ul Dojazd 16A 33 100 Tarn w Wy czny dystrybutor nowoczesnych system w www hymon pl 38...

Page 39: ...has been subjected to several tests to ensure its optimal operation and reliability Please set the proper grid parameters according to the requirements of your current country s grid regulations If y...

Page 40: ...the memory error Failure in writing memory EEPROM Restart the inverter if the fault still exists contact your installer or Deye service 1 It tells the DC 12V is not existed 2 Restart the inverter if...

Page 41: ...ontact your installer or Deye service F35 No AC grid 1 Check AC grid voltage Check AC voltage detection circuit Check if the AC connector in good condition Check whether the AC grid is normal in volta...

Page 42: ...f the AC cable is too thin Check the voltage difference between LCD and meter F42 AC Line W U low voltage Check the AC voltage protection setting Check the voltage difference between LCD and meter Als...

Page 43: ...r voltage is too low 1 It tells the PV input voltage is low and it always happens in the early morning 2 Check PV voltage and Ubus voltage When inverter is running then showing F56 maybe Loss of drive...

Page 44: ...50 60 Optional Three phase BPT V03 15 19 5 11 22 2 1 2 15 16 5 21 8 23 9 0 8 leading 0 8 lagging 3 Grid Current THD 330 430 193 5 Transformerless Size mm W H D 17 Weight kg Topology 1W Night Internal...

Page 45: ...Hymon Fotowoltaika Sp z o o ul Dojazd 16A 33 100 Tarn w Telefon Fax 48 575 910 300 E mail biuro hymon pl...