Troubleshooting
Fault
Possible cause
Remedy
Excessive vibration
or/and Unusual noises
Imbalance due to worn or broken tools.
Defective bearing.
Wrong tension of the belt.
Defective motor.
The scarify setting is too deep.
Replace all worn or broken parts.
Check the bearing on the axle drive
shaft and replace if necessary.
Check the tension of the belt, replace
the belt if necessary.
Replace the motor.
Reduce the working depth.
Reduced or no
performance
Tools have reached the maximum
permissible wear.
Inappropriate tools for the application.
Replace the worn parts.
Replace the tools with appropriate tools
for the surface to be treated.
Motor does not switch
on
Missed phase.
Wrong phase sequence.
Defective Component.
Dead man’s switch is not a
ctivated.
Check the mains power supply and try
to switch on again.
Adjust phase sequence.
Find fault and replace defective
component.
Put the key of the dead man’s switch in.
Motor protection switch
triggers while running
Motor protections switch triggered because
of overload .
Motor has a defect.
Reduce the working depth and / or
advancing speed.
Check the motor.
Drive unit does not
respond
Paddles are not pushed in
Push the paddles in engaging position.
Summary of Contents for BMP-335
Page 1: ...Original instructions in English language OPERATING INSTRUCTIONS BMP 335 ELITE VERSION 1 0...
Page 12: ...12 www blastrac eu 4 4 Tilting the machine backwards 1 2 3 4 5 6...
Page 14: ...14 www blastrac eu 4 6 Electric drive 1 2 3 4 5 6...
Page 18: ...18 www blastrac eu CW Rotating direction of the drum ClockWise normal Drum up down quick lever...