Operating manual BDC3140 DBP/LPP
12/12
GB
Troubleshooting
Problem
Cause
Remedy
The vacuum cleaner does not start
Lack of power supply
Check for power at the socket.
Check the condition of the socket and
the cable.
If necessary, ask for assistance to
be performed by a manufacturer’s
technician.
The vacuum cleaner does not vacuum
correctly
Clogged filters
Check the filter cleaning operation or
replace the filters.
Check the compressor functionality
(see the relative manual).
Make sure that the compressed air
nozzles are aligned with the cartridges.
Clogged vacuum hose
Check the vacuum hose and clean it.
The vacuum cleaner suddenly stops
Circuit breaker activation
Check the circuit breaker adjustment.
Check the motor electrical input.
Empty the container.
If necessary, ask for assistance to
be performed by a manufacturer’s
technician.
Dust leaks from the vacuum cleaner
Filters are broken
Replace them with others of identical
type.
Inadequate filter
Replace it with another of a suitable
category and check.
Electrostatic current on the vacuum
cleaner
Non existent or inefficient grounding
Check all ground connections. In
particular on the vacuum inlet fitting;
replace the hose with an antistatic
hose.
Summary of Contents for BDC3140
Page 14: ...Operating manual BDC3140 DBP LPP 2 8 info blastrac eu 1 5 4 6 1 1 2 4 5 6 7 3 8 9 10 11 ...
Page 15: ...Operating manual BDC3140 DBP LPP info blastrac eu 3 8 7 8A 8B 2 1 8 3 1 2 50 mm ...
Page 17: ...Operating manual BDC3140 DBP LPP info blastrac eu 5 8 12 13 14 2 1 2 1 2 3 ...
Page 18: ...Operating manual BDC3140 DBP LPP 6 8 info blastrac eu 15 Q1 Q2 KM1 Q2 Q2 ...
Page 20: ...Operating manual BDC3140 DBP LPP 8 8 info blastrac eu ...