WARNING!

 

Make sure there is no evident sign of damage 

to the vacuum cleaner before starting work.

 

Before plugging the vacuum cleaner into the 

electrical mains, make sure the voltage rating 

indicated on the data plate corresponds to that 

of the electrical mains.

 

Plug the vacuum cleaner into a socket with a 

correctly installed ground contact/connection. 

Make sure that the vacuum cleaner is turned 

off.

 

The plugs and connectors of the connection 

cables must be protected against splashes of 

water.

 

Check that for proper connection to the 

electrical mains.

 

Use the vacuum cleaners only when the cables 

that connect to the electrical mains are in 

perfect condition (damaged cables could lead 

to electric shocks!).

 

Regularly check there are no signs of damage, 

excessive wear, cracks or ageing on the electric 

cable.

WARNING!

When the vacuum cleaner is operating, do not:

 

Crush, pull, damage or tread on the cable that 

connects to the electrical mains.

 

Only disconnect the cable from the electrical 

mains by removing the plug (do not pull the 

cable).

 

Only replace the electric power cable with 

one of the same type as the original: H07 

RN - F (400V/50Hz), SOOW (230V/60Hz 

- 440V/60Hz), the same rule applies if an 

extension is used.

 

The cable must be replaced by the 

manufacturer’s Service Centre staff or by 

equivalent qualified personnel.

Extensions

If an extension cable is used, make sure it is suitable for the 

power input and protection degree of the vacuum cleaner.

Minimum section of extension cables:

Maximum length = 20 m

Cable = H07 RN-F (400V/50Hz) , SOOW (230V/60Hz-440V/60Hz)

Max power (kW)

3

5

Minimum section (mm

2

)

2.5

4

WARNING!

Sockets, plugs, connectors and installation of the 

extension cable must maintain the IP protection 

degree of the vacuum cleaner, as indicated on the 

data plate.

WARNING!

The vacuum cleaner’s power socket must be 

protected by a differential circuit-breaker with 

surge current limitation, that shuts off the power 

supply when the current discharged to the 

ground exceeds 30 mA for 30 ms or an equivalent 

protection circuit.

WARNING!

Never spray water on the vacuum cleaner: this 

could be dangerous for persons exposed and could 

short circuit the power supply.

Dry applications

[ NOTE ]

The supplied filters and the bag (if applicable) must be 

installed correctly.

WARNING!

Comply with the safety regulations governing the 

materials for which the vacuum cleaner is used.

Maintenance and repairs

WARNING!

Disconnect the vacuum cleaner from its power 

source before cleaning, servicing or replacing parts; 

the plug must be removed from the socket.

 

Carry out only the maintenance operations 

described in this manual.

 

Use only original spare parts.

 

Do not modify the vacuum cleaner in any way.

Failure to comply with these instructions could 

jeopardize your safety. Moreover, such action would 

immediately void the EC declaration of conformity 

issued with the device.

Summary of Contents for BDC3140

Page 1: ...ations 5 Maintenance and repairs 5 Technical specifications 6 Dimensions 7 Controls indicators and connections 7 Inspections prior to starting 7 Starting up 7 Emergency stopping 8 Emptying the dust container 8 Operation of the filtering cartridges 8 Tilting discharge device replacement and use BDC3140 LPP 8 Single plastic bag replacement and use 8 Maintenance cleaning and decontamination 9 Filter ...

Page 2: ...eople property and the environment Comply with the safety indications and prescriptions in this instruction manual Proper uses This vacuum cleaner is suitable for commercial use in hotels schools hospitals factories shops offices and apartment hotels for example for hire and in any case for purposes other than normal domestic use This vacuum cleaner was conceived to clean and collect solid and liq...

Page 3: ...ak short circuit motor block electric shock etc Turn the vacuum cleaner off unplug it and request assistance from qualified personnel WARNING The vacuum cleaners must not be used or stored outdoors in damp places These devices cannot be used in corrosive environment EC Declaration of conformity Every vacuum cleaner comes with a CE Declaration of conformity See fac simile in fig 17 NOTE The Declara...

Page 4: ...cleaner on fit the suction hose into the inlet and then fit the required tool on to the end part Refer to the manufacturer s accessory catalogue or Service Centre in order to choose the accessory to be used This vacuum cleaner is equipped with an internal baffle plate which subjects the vacuumed substances to a circular centrifugal movement that makes them drop into the container The vacuum cleane...

Page 5: ...e staff or by equivalent qualified personnel Extensions If an extension cable is used make sure it is suitable for the power input and protection degree of the vacuum cleaner Minimum section of extension cables Maximum length 20 m Cable H07 RN F 400V 50Hz SOOW 230V 60Hz 440V 60Hz Max power kW 3 5 Minimum section mm2 2 5 4 WARNING Sockets plugs connectors and installation of the extension cable mus...

Page 6: ...solute H filter surface HEPA 14 according to MPPS method EN 1822 m2 3 5 3 5 3 5 When the compressor is operating Parameter Units BDC3140 DBP LPP Voltage frequency V Hz 230 60 400 50 440 60 Power rating kW 4 6 4 6 3 Noise level 3 3 1 meter dB A 72 71 80 Peak noise dB A 75 82 81 Protection IP 55 55 55 Motor insulation Class F F F Container capacity Gallons litres 26 100 26 100 26 100 Inlet diameter ...

Page 7: ... vacuum hose and tools have been correctly fitted into the inlet 1 The bag or safety container is installed if applicable Do not use the device if the filter is faulty Starting up Figure 6 1 Castor brakes Lock the castor brakes before starting the vacuum cleaner 1 Starting stopping the vacuum cleaner Turn the switch 3 figure 4 to I position to electrically power the vacuum cleaner The voltage pres...

Page 8: ...dge 2 and the next set on 30 seconds T1 opening time of the solenoid valve for backwashed air exhaust into the cartridge set at 2 tenths of a second The shorter the time the more energetic the cleaning action will be Check the arrows on the knobs of the timer 3 for the exact regulation Factory setting should not be changed if without consulting Blastrac The three solenoid valves of the electropneu...

Page 9: ...d spilling the vacuumed dust and or material Place the disassembled and or replaced filters in a sealed plastic bag Close it hermetically Dispose of the filters in accordance with the laws in force WARNING Filter replacement is a serious matter The filters must be replaced with ones of identical filtering surface characteristics Otherwise the vacuum cleaner will not operate correctly Filter cartri...

Page 10: ...roken or badly connected to the unions it must be replaced When sticky materials are treated check for possible clogging along the hose 2 in the inlet and on the baffle plate inside the filtering chamber Scrape the inlet from the outside and remove the deposited waste as indicated in the figure Figure 13 1 Seal 2 Screws 3 Filtering chamber Filtering chamber tightness check If the gasket 1 between ...

Page 11: ...st of spare parts that should be kept ready at hand in order to speed up maintenance operations Refer to the manufacturer s spare parts catalogue when ordering spare parts Description Code Primary cartridge filter 490803 1 Filter ring seal Z8 17026 Filter chamber gasket 40000762 Absolute filter 4081700936 ...

Page 12: ... compressed air nozzles are aligned with the cartridges Clogged vacuum hose Check the vacuum hose and clean it The vacuum cleaner suddenly stops Circuit breaker activation Check the circuit breaker adjustment Check the motor electrical input Empty the container If necessary ask for assistance to be performed by a manufacturer s technician Dust leaks from the vacuum cleaner Filters are broken Repla...

Page 13: ...Operating manual BDC3140 DBP LPP info blastrac eu 1 8 1 2 3 1 9 10 6 12 5 8 7 15 3 11 2 13 14 4 VOLT 16 ME77 Typ S3 1 13 A S N 07AJ814 3000 W Kg 71 Ref No 4010300258 50 60 Hz 44 B C A B C A ...

Page 14: ...Operating manual BDC3140 DBP LPP 2 8 info blastrac eu 1 5 4 6 1 1 2 4 5 6 7 3 8 9 10 11 ...

Page 15: ...Operating manual BDC3140 DBP LPP info blastrac eu 3 8 7 8A 8B 2 1 8 3 1 2 50 mm ...

Page 16: ...Operating manual BDC3140 DBP LPP 4 8 info blastrac eu 9 10 11 2 3 T3 T2 T1 1 10 6 9 8 1 2 4 3 7 6 11 5 10 4 3 5 1 2 4 5 6 3 ...

Page 17: ...Operating manual BDC3140 DBP LPP info blastrac eu 5 8 12 13 14 2 1 2 1 2 3 ...

Page 18: ...Operating manual BDC3140 DBP LPP 6 8 info blastrac eu 15 Q1 Q2 KM1 Q2 Q2 ...

Page 19: ... EL vastavuse deklaratsioon Kinnitame omal vastutusel et esilehel kirjueldatud masin on vastavuses ulalmainitud direktiivide ja määrustega Käesolev deklaratsioon kaotab kehtivuse juhul kui masinat modifitseeritakse ei peeta kinni kasutamis ja hooldusjuhendis ettenähtud reeglitest EUROOPAN YHTEISÖN DIREKTIIVIT EU VAATIMUSTENMUKAISUUSVAKUUTUS Vakuutamme omalla vastuullamme että lehden etupuolella ku...

Page 20: ...Operating manual BDC3140 DBP LPP 8 8 info blastrac eu ...

Reviews: