Operating Instructions
500 E Global
Fault diagnosis
4
Fault Possible
cause Remedy
Excessive
wear in blast
housing and
recovery duct
Wrong abrasive.
Incorrect setting of the
control cage
Contact
Blastrac BV
.
The thrown abrasive
blasts the housing and
not the surface to be
blasted. Adjust the blast
pattern.
Machine is not
moving
The travel speed is too
low.
Increase the travel
speed.
9.2 Fault diagnosis - electrical system
Prior to any repair works on the machine or its drives the
machine must be secured against unintentional switching-on.
Put the machine to its Safety off position
.
Fault Possible
cause Remedy
Control
system does
not switch on
Motor protection switch
has triggered.
Check and switch on
again. Check the mains
power supply.
Summary of Contents for 500 E Global
Page 1: ...Operating Instructions 500 E Global MAN 500E Global EN REV 0...
Page 2: ......
Page 4: ......
Page 42: ...Operating Instructions 500 E Global Transport 4...
Page 50: ...Operating Instructions 500 E Global Initial operation 8...
Page 58: ...Operating Instructions 500 E Global Operation 8...
Page 72: ...Operating Instructions 500 E Global Maintenance 14...
Page 74: ...Operating Instructions EBE 500 E Electrical systems 2...
Page 75: ...500 E Global Operating Instructions Electrical systems 3 8 1 Electric circuit diagrams...
Page 76: ...Operating Instructions EBE 500 E Electrical systems 4...
Page 90: ...Operating Instructions EBE 500 E Electrical systems 18...
Page 96: ...Operating Instructions 500 E Global Fault diagnosis 6...
Page 97: ...500 E Global Operating Instructions Spare parts 1 Contents Chapter 10 10 1 Spare parts...
Page 99: ...500 E Global Operating Instructions Spare parts 3 10 1 Spare parts Fig 10 1...
Page 102: ...Operating Instructions 500 E Global Spare parts 6 Fig 10 3...
Page 106: ...Operating Instructions 500 E Global Spare parts 10...
Page 108: ...Operating Instructions 500 E Global Spare parts 12 Fig 10 7...