Relative
Humidity
20%...80% sustainable 10%...90% short time
Pressure
86...105kpa
Door & Window
Installing rubber strip for sealing door-gaps and dual level glasses for
window
Wall
It can be covered with wallpaper, or brightness less paint.
Fire Protection
Fire alarm system and extinguisher
Power
Requiring device power, air-conditioning power and lighting power are
independent to each other. Device power requires AC power 100-240V
50-60Hz. Please carefully check before running.
Grounding Requirement
All function modules’ good grounding is the basis of reliability and stability of devices. Also,
they are the most important guarantee of lightning arresting and interference rejection.
Therefore, this system must follow this rule.
Coaxial cables outer conductor and isolation layer should keep proper electric conducting with
the metal housing of device.
Grounding conductor must adopt copper conductor in order to reduce high frequency
impedance, and the grounding wire must be as thick and short as possible.
Users should make sure the 2 ends of grounding wire well electric conducted and be antirust.
It is prohibited to use any other device as part of grounding electric circuit
The area of the conduction between grounding wire and device’s frame should be no less than
25mm
2
.
Frame / Rack Grounding
All the machine frames should be connected with protective copper strip. The grounding wire
should be as short as possible and avoid circling. The area of the conduction between grounding
wire and grounding strip should be no less than 25mm
2
.
Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
Wire Connection
The grounding wire conductive screw is located at the right end of rear panel, and the power switch, fuse,
power supply socket is just beside ,whose order goes like this, power switch is on the left ,power supply
socket is on the right and the fuse is just between them.
Connecting Power Cord
The user can insert one end into the power supply socket, while insert the other end to AC power.
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt independent way, say, share the
same ground with other devices. When the device adopts united way, the grounding resistance should