background image

19

PALIOS-IPM2

Part N

o

: 5105.01

SBL

8 pole IP-/ ASI-TV Modulator

IP/ SFP/ ASI (MPEG2) 

 ATV (8x AM)

SNMP option

The SNMP adjustment is only available after the “SNMP“ option was enabled 
(see chapter “Enabling of“). 
In the first section, the SNMP functionality, including the sending of traps is 
enabled or disabled with the “Mode“ selection field. With the selector “Version“ 
you can select the SNMP version (version 1, 2 or 3). In the two boxes below it, the 
communities for versions 1 and 2 are given separately for reading and writing via 
SNMP. With version 3, these two fields are disabled because all registered users 
of the module (see menu “Passwords“) have the automatic read access to SNMP. 
The write access can be enabled or disabled for each user by clicking the SNMP-
check box in the “Passwords“ menu.
By clicking the “MIB“ button the MIB of the module is generated and offered for 
download.

In the second section the trap settings are done. First, the trap version is selec-
ted:
V1 trap -   normal traps according SNMPv1 with specified community
V2 trap -   normal traps according SNMPv2 with specified community
V2 inform - sends information traps according SNMPv2 and waits for an acknow- 
   

ledgment

V3 trap -   normal traps according SNMPv3
V3 inform - sends information traps according SNMPv3 and waits for an acknow- 
   

ledgment

The community can be configured for traps of SNMP versions v1 and v2. User/ 
password and the using of the network MAC address as the engine ID can be 
configured for traps of SNMP version v3. These settings must correspond with 
the configuration of the trap receiver, so traps are successfully transferred. For 
this purpose a test trap can be sent by clicking the button “Test“ to test the trans-
mission of traps. If a test trap triggered, all pre-preserved traps are discarded.

There up to 256 IP addresses to receive the traps can be created or enabled. 
These are listed under “Receiver IP“. Below, the events can be configured, 
whether and partly with what thresholds they should trigger traps. There are three 
ways to configure a trap:
- without parameters, e.g. fan on/ off
- with a freely selectable parameter for a medium priority
- with a selectable parameter from a list for a medium priority

References and notes:

All users using SNMPv3 must use passwords with at least 8 characters. For SNMPv3 the SBL supports only the authentication 
password, not the privacy password. The SBL only supports the MD5 algorithm for authentication password in SNMPv3.
Information traps are specific traps that are possible up to SNMPv2. If there is no acknowledgment of the receiver, the transmitter 
attempts to transmit it later, until the confirmation is received.
A SBL module holds up to 256 information traps that could not be sent successfully. If there are more unconfirmed traps, the older 
traps are discarded and noted in the logbook as having failed. A successful sent trap is also registered as such in the logbook. In 
case of power failure or reboot of the module the non-confirmed traps are lost.
Details may be found in the help text for each event. The critical priorities are each covered with fixed values   that can not be changed.
If the web site of QAMOS-IP module is open, no changes are possible via SNMP.

Passwords

Again, this setting appears only when you are logged in as administrator, having
the authority to make administrative changes. In addition the box “User and key-
word check“ in the submenu “GUI settings“ has to be clicked. The user ID and
password for the administrator can be set in the first line. The fixing of up to
8 user identification and passwords is possible. The limitations of user rights exist
only in the fact that they are not authorized to change web server settings, user
rights and password changes and default settings.
The default 

password

 for the 

admin

 is:  

1111

   

and for the 

user

s: 

0000

If the SNMP option is enabled, to the right of each user appears an SNMP check
box. By clicking the box, the writing rights for individual users can be awarded for 
the SNMP version 3 (see also section SNMP option).

Summary of Contents for 5105.01

Page 1: ...Professional Headend Solutions Operating instructions PALIOS IPM2 Part No 5105 01 8 pole IP ASI TV Modulator IP SFP ASI MPEG2 ATV 8x AM...

Page 2: ...Status LED s 5 6 5 LED s at the 10 100 Mbit control port 5 7 Adjusting by web server 6 7 1 Network connection to the computer 6 7 2 Setting of individual parameters 7 7 2 1 Menu Overview 8 7 2 2 Menu...

Page 3: ...ted vertically The ventilation slots as well as the circulation perforation of the modules is not be obstructed in any way If installed in mounting cabinets a adequate heat circulation must be guarant...

Page 4: ...tion and sum level adjustment the cable signal is coupled through a directio nal coupler to the output jacks 6 Meaning of the LED s 6 1 LED s at the 10 100 1000 Mbit stream port 1 Designation colour S...

Page 5: ...f display POWER green permanently on module is on amber permanently on module is in standby off module is off operating voltage is not applied SYSTEM green permanently on module is ready for work flas...

Page 6: ...P address within the network To do so the address of the network port on the PC temporary must be adapted to the IP address of the SBL module subnet mask 255 255 255 0 IP address 192 168 1 XXX where X...

Page 7: ...may be selected so that the help appears in the status bar of your browser If appro priate setting changes in the browser options are necessary In addition in the lower part of the navigation tree sta...

Page 8: ...sh top right 7 2 1 Menu Overview This page provides a status overview of the 8 channels If a channel is working without errors SYNC is displayed If errors occur you will see an Error display If the RF...

Page 9: ...is available only after enabling the associate software option see section 7 2 6 The IP address subnet mask and gateway can be configured for each port The next step is to configure the setup paramete...

Page 10: ...how to switch Inclusion in the monitoring is configured on a per channel basis This is a global option deciding when to switch either when an input channel is down or all monitored channels have fail...

Page 11: ...xt both columns there can be selected the language respective the language of the subtitles if there are more than one of them In the column Output frequency there is to be selected the output channel...

Page 12: ...ID of the selected program Type displays the type of the program Language selection of the available language Direct input selection selection menu direct input see be low Selected program variant 2...

Page 13: ...TSC Video format selection letterbox center cut 1 1 pillarbox 4 3 vertical cut 20 9 letterbox Audio setting of the audio parameters Audio gain adjustment range 6 20 dB Audio mode selection 1 mono L mo...

Page 14: ...standard table alternative table no country code English German Swedish Italian French Spanish Czech Rumanian Polish Esto nian Latvian Serbian Turkish Danish only available if Subtitling option is en...

Page 15: ...selection of the user interface language is executed You can choose between German and English The transition can be made either to the left in the navigation tree in the subtree of the point language...

Page 16: ...rowser pages is greatly reduced So it is possible to adjust the module if there is only a low speed connectivity GSM The available reduction is achieved by reducing image size Output frequency raster...

Page 17: ...ad of the current PA LIOS IPM2 releases the current QAMOS IP release is to select and then perform the update process If the option is not enabled after selecting the QAMOS IP releases appears op posi...

Page 18: ...nfigure the DHCP range from which the IP addresses of the connected clients are assigned The address range must match the address range according to IP address and subnet mask of the server and should...

Page 19: ...configured whether and partly with what thresholds they should trigger traps There are three ways to configure a trap without parameters e g fan on off with a freely selectable parameter for a medium...

Page 20: ...e release is displayed 7 2 8 Menu Level With the top box the loop through output loop is enabled or disabled If enabled the underlying selection of the nominal level for all 8 channels may be set in t...

Page 21: ...It lists only the current va lues the naming of the parameter appears in the help box in the lower part of the user interface or in the status bar of the browser as adopted configuration if you hover...

Page 22: ...eboot i e the module restarts and all stored values are adjusted If the module is to be reset to factory settings the reset button must be pressed so long to keep up until the POWER and SYSTEM LED wil...

Page 23: ...SFP CONTROL STREAM IP TS ASI TS 8xPAL PALIOS IPM2 ASI RJ45 SFP CONTROL STREAM IP5 IP3 IP4 IP2 IP1 SWITCH ETHERNET PALIOS IPM2 HELIOS PALIOS IPM2 LANIOSs PALIOS IPM2 ASI signal input IP signal input 1...

Page 24: ...processing EN 50083 9 1 MPEG decoder Video MPEG 2 MP ML Audio Audio description MPEG 1 Layer 1 2 TV output TV standard B G D K Sound type double carrier FM Sound carrier frequencies B G 5 5 5 742 MHz...

Page 25: ...eams 2 EN 60728 11 Cable networks for television signals sound signals and interactive services Part 11 Safety IEC 60728 11 2005 German version EN 60728 11 2005 3 EN 50083 2 Cabled distribution system...

Page 26: ...the conformity of the product Product name IP ASI TV Transmodulator Type PALIOS IPM2 Product number 5105 01 according to the following regulations EN 50083 2 3 EN 60728 11 2 as far as relevant and add...

Reviews: