BlackHawk Labs MiniRaQ Installation Overview Download Page 8

www.miniraq.com

PAGE 8

MiniRaQ

Specifications

(TM)

Item Measurement

Height

:

 19.25 in (489 mm)

Width

:

 19.00 in (483 mm)

Depth:

4U version

:

 9.50 in (241 mm)

6U version

:

 13.00 in (330 mm)

8U version

:

 16.50 in (419 mm)

Net 

W

eight:

4U version

:

 1

3

.0 lb (5.

9

 kg)

6U version

:

 1

6

.0 lb (

7.3

 kg)

8U version

:

 1

9

.0 lb (

8.6

 kg)

Maximum Equipment Depth 38.00 in (965 mm)

Effective Rack Mounting Space:

4U version 4U + 2U Patch Panel + 1U each on Sides = 8U

6U version 4U + 2U Patch Panel + 1U each on Sides = 10U
8U version 4U + 2U Patch Panel + 1U each on Sides = 12U

Total Equipment Weight Capacity: 400.00 lb (181.44 kg)

Material: Heavy Duty 14AWG Steel

Finish: 

Chip Resistant Black Powder Coat

Shipping Dimensions: 

20 X 20 X 3 inches All Versions

Shipping Weight:

4U version

:

 1

5.

0 lb (

6.8

 kg)

6U version

:

 1

8

.0 lb (

8.2

 kg)

8U version

:

 

21

.0 lb (

9.5

 kg)

Pallet Quantity

:

 48

Specifications are subject to change

.

Summary of Contents for MiniRaQ

Page 1: ...d in this manual please consult local building code requirements to insure safe and secure installation TM www miniraq com PAGE 1 All Trademarks are the property of their respective owners Patents pending BlackHawk Labs LLC Copyright 2007 Warning Back plate of is designed with 3 mounting options A hole pattern 10 B Slots are centered at 16 inches for 10 by 2 screws 10 into studs or other solid woo...

Page 2: ...olts before continuing with installation 10 fasteners are recommended for full rated load 10 fasteners are recommended for full rated load TM 2 Post Rack mounting option Hole Pattern A Page 3 Mounting to Cinder Block or Approved Hollow Wall Hole Pattern C Page 5 Mounting to Concrete Wall with Compression Lags Hole Pattern C Page 6 Mounting to Concrete Wall with TAPCON bolts Hole Pattern C Page 6 P...

Page 3: ... panel and add second screw to opposite post Add remaining 8 screws and then tighten all Next go to bracket installation details pg 7 Begin installing 12 24 Screws at the top using the integrated Level to locate proper mounting pattern 10 screws recommended for full payload rating of system Secure both top and bottom of 2 Post Relay Rack before loading MiniRaQ TM Close up detail of 2 Post Mounting...

Page 4: ...unting into 16 inches on center solid wood wall studs Hole Pattern B Place the MiniRaQ TM main back panel against the wall in the preferred location Confirm location of stud centers and for at least one TOP pilot hole Drill pilot hole using 5 32 bit not supplied Place the first 10 wood screw through top slot B and insert screw most of the way into stud Using integrated level adjust panel and drill...

Page 5: ...ole is 1 2 bolts and washers not supplied available for purchase separately TM Mounting to Cinder Block or Approved Hollow Wall Hole Pattern C Place the MiniRaQ main back panel against the wall in the preferred location Using integrated level adjust panel to level thenmark a of the two top and two bottom inch clearance holes Hole C Drill marked holes and apply Togglers or other associated inserts ...

Page 6: ...supplied most of the way into wall Tighten all screws Next go to bracket installation details pg 7 TM minimum Mounting to Concrete Wall with Compression Lags Hole Pattern C Place the MiniRaQ main back panel against the wall in the preferred location Refer to Figure 5 on Page 5 for correct mounting hole pattern Using integrated level adjust panel and to level and mark a of the two top and two botto...

Page 7: ...The Bracket Installation Details for System MiniRaQ TM Engage one bracket at a time confirming all tabs are nested into cutouts on MiniRaQ main back panel 1 and slide down to fully set bracket The clearance hole in the bracket 2 should now align with a threaded hole in the MiniRaQ main back panel Apply a 12 24 screw supplied and tighten Repeat with opposite bracket TM TM Bracket Arm Security screw...

Page 8: ...0 in 965 mm Effective Rack Mounting Space 4U version 4U 2U Patch Panel 1U each on Sides 8U 6U version 4U 2U Patch Panel 1U each on Sides 10U 8U version 4U 2U Patch Panel 1U each on Sides 12U Total Equipment Weight Capacity 400 00 lb 181 44 kg Material Heavy Duty 14AWG Steel Finish Chip Resistant Black Powder Coat Shipping Dimensions 20 X 20 X 3 inches All Versions Shipping Weight 4U version 15 0 l...

Page 9: ...e alleged defect in the product does not exist or was caused by end user s or any third person s misuse negligence or improper installation Further BHL shall not be liable under the warranty for unauthorized attempts to repair or modify inappropriate on site operating conditions corrosive atmosphere installation a change in location or operating use exposure to the elements Acts of God fire theft ...

Page 10: ...FFICER AND LEGAL DEPARTMENT Customers with warranty claims issues may access the BHL worldwide customer support network by visiting www bhpower com support Customer support for this or any other BHL product is available at no charge in any of the following ways Visit www MiniRaQ com web site to access documents and to submit customer support requests www bhpower com Corporate Headquarters 877 427 ...

Reviews: