User Manual
Publication date: March, 2006
Revision A2
174
autologout
autologout
Syntax
:
autologout <time>
Description
:
To set up the timer of autologout.
Argument
:
<time>: range 1 to 3600 seconds, 0 for autologout off, current setting is 180
seconds.
Possible value:
<time>: 0,1-3600
Example:
FEML2-SW26M# autologout 3600
Set autologout time to 3600 seconds
bandwidth
set egress-rate
Syntax
:
set egress-rate <range> <data_rate>
Description
:
To set up the egress-rate of the ports.
Argument
:
<range>:syntax 1,5-7, available from 1 to 26
<data_rate>: 66-1024000(Kb).
port 1-24: 66-102400(Kb); port 25-26: 66-1024000(Kb)
Possible value:
<range>: 1 to 26
<data_rate>: port 1-24: 66-102400(Kb); port 25-26: 66-1024000(Kb)
Example:
FEML2-SW26M(bandwidth)# set egress-rate 1-16 299
set ingress-rate
Syntax
:
set ingress-rate <range> <data_rate>
Description
:
To set up the ingress-rate of the ports.
Argument
:
<range>:syntax 1,5-7, available from 1 to 26
<data_rate>: 66-1024000(Kb).
port 1-24: 66-102400(Kb); port 25-26: 66-1024000(Kb)
Possible value:
<range>: 1 to 26
<data_rate>: port 1-24: 66-102400(Kb); port 25-26: 66-1024000(Kb)
Example:
FEML2-SW26M(bandwidth)# set ingress-rate 1-16 100