161
show mode
Syntax
:
show mode
Description
:
To display the mode of each port.
Argument
:
None.
Possible value:
None.
Example:
FEML2-SW26M(802.1x)# show mode
Port Mode
====== ============
1 Disable
2 Multi-host
3 Disable
4 Disable
5 Disable
6 Disable
:
:
:
show parameter
Syntax
:
show parameter
Description
:
To display the parameter settings of each port.
Argument
:
None.
Possible value:
None.
Example:
FEML2-SW26M(802.1x)# show parameter
port 1) port control : Auto
reAuthMax : 2
txPeriod : 30
Quiet Period : 60
reAuthEnabled : ON
reAuthPeriod : 3600
max. Request : 2
suppTimeout : 30