Page 16
724-746-5500 | blackbox.com
LongSpan 900-MHz Wireless Ethernet Tube Housing Kit
A plug-in wall transformer is included with the housing. The transformer out-
puts 24 VAC. Determine where the transformers will be located, then run a set of
power wires into the cable strain relief. Use the chart below to determine the cor-
rect wire gauge needed based on the length of the run.
Table 4-1. 24-VAC wiring distances.
Wire Gauge
22
20
28
16
14
12
10
Total VA
35
44
70
112
179
285
452
Consumed
1. Run 24-VAC power through a cable strain relief (separate from the Ethernet).
Place stripped power wire ends into the power board terminals marked 24
AC (in).
2. Secure the ground wire to the screw located in the bottom rear of housing.
3. Tighten the terminal block screws, then tighten the cable strain relief.
Heater 24 VAC (IN)
24-VAC
(camera)
Blower
(black)
Blower
(red)
Figure 4-5. Terminal block connections.
4. Connect the Ethernet (RJ-45) cable from the wireless unit to the network
camera See Figure 4-1.