DSP information window
140
Model LRA2900A RAS Administrators’ Reference Guide
10 • Digital Signal Processing (DSP)
•
hardwareFailure(1)—During power up a self test routine detected a problem with this DPS. It will not be
booted with code or used for calls.
•
pendingBoot(2)—Software on this DSP has stopped acting properly. This DSP will not be used for calls. At
the next convenient time the DSP will be rebooted.
•
booting(4)—The DSP has just been loaded with code and we are now waiting for an indication from the
DSP that the code loaded properly and is running.
•
unavailable(5)—The instance is fully operational and could be used to take a call except that the administra-
tor has indicated that this instance should not be used.
•
reserved—The instance is fully operational and could be used to take a call. But, another DSP in the same
boot group as this one is pendingBoot. Therefore we are not to use this until the reboot occurs.
•
suspect(7)—The instance is operational and could be used to take a call. But, we have seen a number of
consecutive failures so it will not be used until no other available instances can be found. A successful call
will place this instance back into the available state.
•
available(8)—The instance is fully operational and can be used to take a call
Instance First Used By (dspUseFirst)
Identifies whether the first instance is in use or free.
Instance Second State (dspStateSecond)
Identifies the current state of the second instance of the DSP. See dspStateFirst for parameter values.
Instance Second Used By (dspUseSecond)
Identifies whether the second instance of the DSP is in use or free.
Call Statistics
This portion of the DSP information window (see figure 42 on page 139) shows the statistics of the individual
DSP.
Originating Calls (dspOriginatingCalls)
The number of calls the DSP initiates for outbound calls.
Answering Calls (dspAnsweringCalls)
The number of calls answered regardless if the call was successfully completed.
Successful Connects (dspSuccessfulConnects)
The number of calls that successfully connected.
Failed Connect (no far modem) (dspFailedConnectPreV8)
The number of calls that failed before modulation V8 was completed.
Failed Connect (bad negotiation) (dspFailedConnectPostV8)
The number of calls that failed to after V8 modulation was completed.
Summary of Contents for LRA 2900
Page 29: ...Contents Model LRA2900A RAS Administrators Reference Guide 29 ...
Page 33: ...About this guide Model LRA2900A RAS Administrators Reference Guide 33 ...
Page 63: ...5 Authentication Model LRA2900A RAS Administrators Reference Guide 63 Modify Static User ...
Page 72: ...72 Model LRA2900A RAS Administrators Reference Guide 7 Dial In ...
Page 201: ...16 MFR Version 2 Model LRA2900A RAS Administrators Reference Guide 201 ...
Page 211: ...16 MFR Version 2 Model LRA2900A RAS Administrators Reference Guide 211 MFR Version 2 Modify ...
Page 268: ...268 Chapter 22 About Chapter contents Introduction 269 Black Box contact information 269 ...
Page 273: ...23 License Model LRA2900A RAS Administrators Reference Guide 273 End User License Agreement ...
Page 278: ...278 Appendix B MIB trees Chapter contents Model LRA 2900 MIB Tree Structure 279 ...