6.1 POINT-TO-POINT INSTALLATION
In a point-to-point configuration, no administrator setup of the Emerald SE Transmitter or the Emerald SE Receiver is required.
This enables you to install the system quickly, directly out-of-the-box. However, in the point-to-point configuration, you can install
only one Emerald SE Transmitter and Emerald SE Receiver pair on a subnet, and both must be on the same subnet unless a router
is present in the network to span subnets.
Also if there are other devices with 192.168.1.21 (default Receiver IP address) or 192.168.1.22 (default Transmitter IP address) on
the network, then the IP addresses for Receiver and/or Transmitter should be changed to unused IP addresses.
6.2 UNMANAGED OR MANAGED MATRIX INSTALLATION
The following instructions will enable you to install your Emerald SE Receiver and Emerald SE Transmitter in a networked
configuration. In this installation, multiple Emerald SE Transmitters and Emerald SE Receivers are attached via the same Ethernet
network. In this case, it is important for each unit to be configured with a unique IP address.
The Emerald SE Receiver has been preconfigured with factory-default network settings. If you install multiple units on the same
network, you will need to assign a unique IP address to each unit or configure the Receiver for DHCP. This can be done via the
On-Screen Display (OSD) on the Emerald SE Receiver and must be carried out before adding multiple devices on the same network.
TABLE 6-1. EMERALD SE SYSTEM DEFAULT NETWORK SETTINGS
COMPONENT
IP ADDRESS
TYPE
DEFAULT GATEWAY
SUBNET MASK
Emerald SE Receiver (EMD2000SE-R, EMD2002SE-R)
192.168.1.21
Static
192.168.1.1
255.255.255.0
Emerald SE Transmitter (EMD2000SE-T, EMD2002SE-T)
192.168.1.22
Static
192.168.1.1
255.255.255.0
Boxilla Manager (BXAMGR)
192.168.1.24
Static
192.168.1.1
255.255.255.0