background image

MENSOR MODEL 73 SHOP AIR BOOSTER

Operation Manual - PN 0017946001 A

®

 

 

 

 
 
 
 
 
 
 
 
 

 

 

 
 

Mensor Model 73 

Shop Air Booster System 

(750 psi Version) 

April 23, 2012 

 

Summary of Contents for 73

Page 1: ...MENSOR MODEL 73 SHOP AIR BOOSTER Operation Manual PN 0017946001 A Mensor Model 73 Shop Air Booster System 750 psi Version April 23 2012 ...

Page 2: ...Copyright Mensor is a registered trademark of Mensor Corporation All other brand and product names are trademarks or registered trademarks of their respective companies 2010 Mensor Corporation All rights reserved ...

Page 3: ...Tubing Fittings and connected devices must have a working pressure rating equal to or greater than the maximum required pressure Caution All connections should be in good mechanical condition i e good threads on fittings tubing free of kinks or nicks etc Caution All connections should be properly installed and tightened Caution Small articles exposed to the escaping gas can be propelled at ballist...

Page 4: ... of 70 to 150 psi Absolute Maximum Input Pressure is 150 psi to the rear mounted pressure filter This pressure is regulated down to a typical working pressure of 50 to 150 psi The second pressure port is the HIGH PRESSURE OUTPUT port It is designed for a typical output pressure of 325 to 750 psi The mechanical advantage is derived by using differing piston area sizes to generate high pressures The...

Page 5: ...ply such as shop air to the INPUT PRESSURE port The system requires a minimum of 60 psi to obtain 300 psi output 2 Connect the load pressure controller to the HIGH PRESSURE OUTPUT port Be careful to use tubing rated for the boosted working pressure 3 Slowly apply shop air to the INPUT PRESSURE port while monitoring the OUTPUT PRESSURE gauge on the front of the unit For most applications the booste...

Page 6: ...0 to 150 psi just not at zero If the unit continually cycles after reaching pressure and the temperature of the gas has stabilized or when cycling occurs when not being used 1 Check for leaks in the system Use a leak detector to track down and correct the problem MAINTENANCE NOTE High Pressure Gas can be dangerous Maintenance of this unit should be performed by fully qualified personnel only Boost...

Page 7: ...n the element with a cleaning solvent Dry all the parts and reassemble Make sure that the o ring seal for the bowl is properly positioned replace the bowl and tighten the ring nut by hand The Haskel recommended maintenance schedule is listed in the appendix ...

Page 8: ...egulator Adjust Regulator Gauge 50 to 150 psi Input Pressure Filter See Maintenance Section High Pressure Output Port 750 PSI Max Moisture Trap Release Valve Speed Adjust Lever located inside chassis Input Pressure Port 150 psi Max Rear View ...

Page 9: ... 750 psi with appropriate supply pressure Not to exceed 750 psi maximum Charge Noise Level Approximately 80 dbA intermittent pulses measured at 1 meter Weight 45 lbs or 20 4 kg Size Rack Mounted 7U Chassis 19 wide 10 5 tall 17 25 deep 482 6 mm x 266 7 mm x 438 15 mm User accessible filter extends depth by an additional 5 or 127 mm in the rear ...

Page 10: ...APPENDIX Haskel Operating and Maintenance Instructions ...

Page 11: ...Mensor Corporation 201 Barnes Drive San Marcos Texas 78666 5994 Phone 512 396 4200 Fax 512 396 1820 Web site www mensor com E mail sales mensor com ...