EN
G
LI
SH
ENGLISH
7
10
8
11
7 SHOWER ONLY OUTLET CONNECTIONS
Connect Shower Outlet Pipe (7A) to valve body (7B). Plug bottom outlet (7C) with
Pipe Cap or Plug (7D). Connect Pipe Elbow (7E) (
not included
) to the end of the pipe.
Securely fastened to framing or other solid support.
8 PRESSURE TESTING THE VALVES
(Air testing is not recommended)
NOTE:
Valve function: close-clockwise, open-counterclockwise)
Use a
1
/
2
” iron pipe plug (8B) (
not included
) on shower outlet (8C). Rotate hot and cold
valve stems (8A) to full on position and check all connections for leaks. Rotate hot and
cold valve stems (8A) to off position and look for leaks from the outlets.
CAUTION:
Slowly remove pipe plugs from tub and shower outlets to relieve pressure.
9 UNIT START UP
Turn on water supply inlet valves and check for leaks.
10 SHOWER ARM INSTALLATION
Insert the end of Shower Arm (10A) through the Shower Flange (10B). Apply PTFE
plumber’s tape to both ends of Shower Arm (10A) according to manufacturer’s
instructions. Screw the end of Shower Arm (10A) into pipe elbow inside the wall. Slide
Shower Flange (10B) tight to the wall.
11 FLANGE INSTALLATION
Remove stem protectors (11A) from Valves (11B). Screw Threaded Nipples (11C) into
Valves (11B). Place Protective Washers (11D) onto Valves (11B). Screw Flanges (11E)
onto Threaded Nipples (11C) and hand tighten Flanges (11E
) until snug against wall.
Reverse procedures to remove.
3
7A
7E
7B
7C
7D
10A
10B
11A
11B
11C
11C
11D
11E
11E
11D
11B
8B
8A
8A
8A
8A
8C
OPEN
OPEN
Summary of Contents for Price Pfister 807 Series