Replace  screen  filter,  and  garden 

hose  connector  immediately  to 

prevent  any  foreign  matter  from 

entering the pump. 

  CAUTION:

    Do  not  damage  the 

screen  filter, while removing or cleaning. 

Any foreign particles entering the pump 

may damage the pump. 

COOLING SYSTEM 

The air vents, located in and around the 

pressure  washer,  must  be  kept  clean 

and free of any obstructions to ensure 

proper  air  cooling  of  the  motor  during 

operation. 

  WARNING:

  Prevent  water  from 

penetrating  the  vents  of  the  pressure 

washer to minimize the risk of damage 

to the machine and to reduce the risk of 

shock to the operator. 

STOrAGE

 CAUTION:

 Prior to moving the unit, 

always disconnect the garden hose via 

the garden hose connector.

  CAUTION:

  Always  store  your 

pressure  washer  in  a  location  where 

the temperature will not fall below 40° F 

(4°  C).  The  pump  in  this  machine  is 

susceptible  to  permanent  damage  if 

frozen.

  FREEZE  DAMAGE  IS  NOT 

COVERED BY THE WARRANTY. 

END OF USE AND WINTER 

STORAGE INSTRUCTIONS 

1.  When  finished  using  the  pressure 

washer,  you  must  first  drain  and 

rinse the detergent tank. 

2.  Run  the  pressure  washer  in  low 

pressure  until  all  of  the  soap  is 

drained from the detergent tank. 

3.  Pour clear water into the tank and 

run  it  through  on  low  pressure  as 

though it were detergent. 

NOTICE: 

Failure  to  clean  properly  will 

cause bottle or suction tube to become 

clogged and inoperable.
4.  Turn the machine OFF and squeeze 

the  trigger  to  re lease  the  trapped 

pressure inside of the machine. 

5.  Remove both the garden hose and 

high pressure hose from the unit. 

6.  Disconnect the lance from the gun.
7.  Turn  ON  the  machine  and  allow  it 

to run for 5 seconds. (This will clear 

out  most  of  the  water  trapped  in 

the pump).

8.  Unplug machine .
9.  Wrap  high  pressure  hose  and 

power  supply  cord  onto  storage 

rack  and  snap  power  supply  cord 

into place as shown.

15

10.  Store the machine and accessories 

in  a  dry,  climate  controlled 

environment.  Do  not  store  the 

machine or accessories in a place 

where the temperature could drop 

below 40° F (4° C). 

AccESSOrIES

  DANGER:  Risk  of  fluid  injection. 

When  using  replacement  lances  or 

guns  with  this  pressure  washer,  DO 

NOT  use  a  lance  and/or  lance/gun 

combination that is shorter in length 

than  what  was  provided  with  this 

pressure  washer  as  measured  from 

the  nozzle  end  of  the  lance  to  the 

gun trigger.

NOTICE:  The  use  of  any  other 

accessory not recommended for use 

with  this  tool  could  be  hazardous. 

Use  only  accessories  rated  equal 

to  or  greater  than  the  rating  of  the 

pressure washer.

Summary of Contents for 11BDE-315

Page 1: ...CE AL LUGAR DONDE LA COMPRO Contáctese con nuestro Departamento de Servicio al Cliente llamando al www power washer us o 1 800 381 0999 Save this manual for Future reference VEA EL ESPAÑOL EN LA CONTRAPORTADA INSTRUCTIVO DE OPERACIÓN CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA ADVERTENCIA LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES Pressure Washer Lavad...

Page 2: ...nto place Push as shown to further lock carry handle into place Con la manija orientada como se muestra alinee los surcos adentro el agarador de la maquina p con los carriles encima de la maquina de presión y resbalan dentro de lugar Empuje como se muestra a conectar el agarador de la maquina 1 P AA BB Align slots BB on back of storage rack with ribs AA on back of pressure washer Slide storage rac...

Page 3: ...ton Z then press and release the RESET button X The light on the GFCI should be illuminated X Z C 8 Enchufe el GFCI C a un tomacorriente Presione con firmeza y suelte el botón de prueba TEST Z y luego presione y suelte el botón de reinicio RESET X Se debe encender la luz del GFCI SQUEEZE AND HOLD TRIGGER UNTIL WATER FLOW IS STEADY RELEASE THE TRIGGER MANTENGA PULSADO EL ACCIONADOR HASTA qUE EL CAU...

Page 4: ... harm Wash hands after handling important safety instructions WARNING Please read this entire manual before attempting to assemble operate or install the product If you have any questions regarding the product please contact our customer service department at www power washer us or 1 800 381 0999 WARNING This unit was designed for specific applications It should not be modified and or used for any...

Page 5: ... when not in use and prior to the detaching of the high pressure hose 22 Never tie knots or kink the high pressure hose as da mage could result Inspect the high pressure hose regularly Replace the hose immediately if it is damaged worn or shows any signs of cracks bubbles pinholes or other leakage Never grasp a high pressure hose that is leaking or damaged 23 Do not operate or store this product i...

Page 6: ...normal operation after a short period of time GROUND FAULT CIRCUIT INTERRUPTER PROTECTION This pressure washer is provided with a Ground Fault Circuit Interrupter GFCI built into the plug of the power supply cord This device provides additional protection from the risk of electric shock Should replacement of the plug or cord become necessary use only identical replacement parts that include GFCI p...

Page 7: ...d to an electrical outlet Reset by simply pushing the reset button on the GFCI power plug EXTENSION CORDS Use only extension cords that are intended for outdoor use These extension cords are identified by a marking Acceptable for use with outdoor appliances store indoors while not in use Use only extension cords having an electrical rating not less than the rating of the product Do not use damaged...

Page 8: ... A Spray Gun B Click N Clean Spray Lance C GFCI D Garden Hose Connector factory installed E High Pressure Hose F Safety Lock G Motor and Pump in Case H Power Supply Cord with GFCI I ON OFF Switch J On board Detergent Tank K High Pressure Outlet metal L Shipping Plug M Water Inlet plastic N On Board Accessory Storage Holsters O Water Inlet Filter Screen factory installed inside water inlet M P Carr...

Page 9: ... for the flow rate of water CU Cleaning Units GPM multiplied by PSI GPM x PSI CU Detergent Injection System Mixes cleaners or cleaning solvents with the water to improve cleaning effectiveness Water Supply All pressure washers must have a source of water The minimum requirements for a water supply are 20 psi and 5 gallons per minute If your water source is a well the garden hose length can only be...

Page 10: ... The pressure of the spray on the surface you are cleaning increases as you move the wand closer to the surface CAUTION The High Pressure Jet Stream spray position is very aggressive We recommend that for most cleaning applications a fan spray pattern U or V be used to avoid damage to the surface being sprayed POWERSWIVEL FAN SPRAY WAND FIG 5 CAUTION The red nozzle portion of the lance pivots 360 ...

Page 11: ...t ensures a quick soaking of the dirt allowing the high pressure water to penetrate and remove the dirt more effectively Application of detergent CAUTION Avoid working on hot surfaces or in direct sunlight to mini mize the chance of the soap damaging painted surfaces CAUTION Damage may occur to painted surface if soap is allowed to dry on the surface Wash and rinse a small section at a time 1 Appl...

Page 12: ...source is a well the garden hose length can only be 30 ft maximum ON OFF 9 D Y 3 Insert the spray lance B R into the gun A by pushing firmly and simultaneously twisting a 1 4 of a turn counterclockwise until locked into place 10 A B R WARNING If the lance is not securely locked into place it could be ejected under high pressure during operation possibly causing injury or damage 4 Turn incoming wat...

Page 13: ...hould be cleaned regularly Clogging of the nozzle causes diminished performance and the pump pressure to be too high and cleaning is immediately required 1 Remove the wand from the gun 2 Clear the nozzle by forcing a stiff wire or straightened out paper clip small size through the center hole of each nozzle 3 Backflush the nozzle with water from both ends 4 Reconnect the wand to the gun Restart th...

Page 14: ...ed from the detergent tank 3 Pour clear water into the tank and run it through on low pressure as though it were detergent NOTICE Failure to clean properly will cause bottle or suction tube to become clogged and inoperable 4 Turn the machine OFF and squeeze the trigger to re lease the trapped pressure inside of the machine 5 Remove both the garden hose and high pressure hose from the unit 6 Discon...

Page 15: ... validate this warranty A store issued receipt or credit card statement showing the purchase date is an acceptable warranty validation Please retain one of these documents in your records If you have any questions please contact our customer service department at www power washer us or 1 800 381 0999 What is covered Replacement parts and labor Please note that we reserve the right to repair or rep...

Page 16: ...rupter GFCI which are only covered for 90 days effective from the date of retail purchase and is not transferable This warranty excludes incidental consequential damages and failures due to misuse abuse or normal wear and tear This warranty applies only to products used in consumer home applications This warranty does not apply to commercial or rental applications This warranty gives you specific ...

Page 17: ... not in the Low Pressure Soap position Follow the instructions provided in the Using Detergent paragraph under the Operation Instructions section of this manual Detergent to Water ratio The pressure washer draws detergent at a maximum 10 1 water to detergent ratio Most pressure washer detergents are concentrated within this range If you feel you are using more detergent than is required for the ap...

Page 18: ...alling with this issue Low surging pressure or motor does not stop when spray gun trigger is released NOTE The Pressure washer is NOT receiving a full volume of incoming water The machine requires a pressurized water source capable of sustaining a minimum of 20 psi at 5 gpm Faucet is not fully open Verify incoming water supply faucet is open at the maximum setting Garden hose is too long or it is ...

Page 19: ...rding to instructions provided in Ground Fault Circuit Interrupter Protection paragraph under Power Supply Electrical info in this manual Motor stops working during normal operation NOTE Motor s thermal overload switch is tripping because the motor is overheated Allow the motor to cool for 20 minutes before troubleshooting and the switch will automatically reset Extension cord is too long or wire ...

Page 20: ...he two tabs on the end of the lance must be fully inserted in the gun before the lance will twist and lock If this does not work then remove the bayonet o ring from the end of the lance and attach the lance to the gun without the o ring in place If the lance attaches to the gun without the o ring in place you will need to replace the o ring Please contact our customer service department at www pow...