33
3.1.9 Arbitrary EDIT Menu
Enters data for creating arbitrary waveforms. You can enter data one point at a time, as a value at an
address, draw a line from one point (a value at an address) to another point, create a predefined
waveform, or combine these to create complex waveforms. The valid data values range is -8191 to
8191. The valid waveform memory addresses range from 1 to 16,382.
The data value governs the output amplitude of that point of the waveform, scaled to the instrument
output amplitude. Therefore, a value of 8191 corresponds to positive peak amplitude, 0 corresponds
to the waveform offset, and -8191 corresponds to the negative peak amplitude
.
Figure 24 - Edit Menu
F1: Point
- This menu allows point-by-point waveform editing. When selected, the following
menu is displayed:
Figure 25 - Point Menu
F1: Adrs - Select the current address in the arbitrary waveform memory.
F2: Data - Selects the data point value at the current address. You can change the point
www.
GlobalTestSupply
.com
Find Quality Products Online at: