Permissible mains voltage tolerance (steady-state) normal:
120V: + 6% to - 10% of nominal value
230V: +10% to -10% of nominal value
Mains frequency :
50Hz
Permissible tolerance of mains frequency:
+2 to -2%
Admissible distortion factor of mains voltage: ≤ 5%
Leakage current protective conductor max.:
3.5 mA
Voltage min. = 11V, max. = 14V
Average current drain 400mA
The power source (external battery) must meet the requirements of the power limit in accor-
dance with UL 60950 und IEC 60950-1: 2001, para. 2.5 (limited power source).
9.3
Ambient conditions
Strictly adhere to the following requirements when applying electronic retail scales weighing
and EDP systems, recording units and similar devices, device combinations and spare parts.
For other manufacturers' equipment included in our scope of supply, the respective manufac-
turer's regulations take preference if they deviate from our conditions.
Limit values
Device
family
Protec-
tion
class
as per
IP
Temperature °C Celsius (degF
Fahrenheit)
Relative humidity %
Operation
Storage
Operation
Storage
min.
max.
min.
max.
min.
max.
min.
max.
1
EDP
sys-
tems:
20
+15
(+60)
+30
(+87)
-10
(+14)
+43
(+109)
8
80
20
80
Retail
scales
20
-10
(+14)
+40
(+104)
-20
(-4)
+60
(+140)
90
90
Label
rolls
-10
(+14)
+40
(+104)
+15
(+60)
+35
(+94)
80
30
80
Ticket
rolls
-10
(+14)
+40
(+104)
+30
(+87)
60
60
2
Exter-
nal de-
vices
The limit values of the respective manufacturers apply
1
Moisture condensation of equipment not permissible
2
Unprinted and packaged thermal paper
Summary of Contents for SC II 100
Page 99: ...Operating instructions SC II Annexe 61429850113 en US 99 107 10 Annexe...
Page 103: ...Operating instructions SC II Annexe 61429850113 en US 103 107 Illustration 86 WLAN BWLC2...
Page 104: ...Annexe Operating instructions SC II 104 107 61429850113 en US Illustration 87 WLAN BWLC2...
Page 105: ...Operating instructions SC II Annexe 61429850113 en US 105 107 Illustration 88 WLAN BWLC2...