4.6.2 MODBUS Device Address
Modbus device address means the MODBUS device address of TD210, center will
identify MODBUS device according to this address. The address works when TD210 is
enabled RTU mode.
4.6.3 Interface Settings
1) 1
st
Analog Work Mode and 2
nd
Analog Work Mode
Disable
Collect Once
There are 2 analog quantity ports, IO4 and IO5, with corresponding port are 6 and 7.
When MODBUS is set as RTU mode, analog work mode is normally set as Collect Once,
TD210 will collect the data through corresponding terminal port after receiving MODBUS
command.
2) 1
st
Digital Work Mode, 2
nd
Digital Work Mode and 3
rd
Digital Work Mode
Disable
Input
Output
There are 3 digital quantity ports, IO1, IO2 and IO3, with corresponding port 3, 4 and 5.
When MODBUS is set as RTU mode, digital work mode is set as input or output, TD210
will operate the corresponding terminal port after receiving MODBUS command.
4 Firmware Upgrade
4.4 Please open the Bivocom Config Tool, as below,
1) Configure Serial Port parameters
Baud Rate: 115200
Data Bit: 8
Stop Bit: 1
Parity Bit: None
2)
Click ‘Download Tool’
3)
Click ‘Load’, choose the firmware you want to upgrade
4)
The click ‘Download’