Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770
3
rd
Software Park, Xiamen, China 361000 Fax: +86-592-6211727
www.bivocom.com
10
3.2.3 Terminal Block, Power Cable and Console Cable
Insert the terminal block to modem correctly.
1) Definition of Terminal Block Interface
PIN No.
Signal
Name
Default Function
Extended Function
1
PWR
Power input anode
NA
2
GND
Power Ground
NA
3
IO1
GPIO, able to check dry contact
signal and 3.3 V switch signal,
output 3.3V switch signal
Reserved RS232 RTS
and
TTL RX
4
IO2
GPIO, able to check dry contact
signal and 3.3 V switch signal,
output 3.3V switch signal
Reserved RS232 CTS
and
TTL TX
5
IO3
GPIO, able to check dry contact
signal and 3.3 V switch signal,
output 3.3V switch signal
Reserved RS232 DCD
6
IO4
GPIO, able to check dry contact
signal and 3.3 V switch signal,
output 3.3V switch signal
Customized
pulse
output, pulse counter,
analog quantity input,
Reserved RS232 RI
7
IO5
GPIO, able to check dry contact
signal and 3.3 V switch signal,
output 3.3V switch signal
Customized
pulse
output, pulse counter,
analog quantity input
8
GND
Power Ground
NA
9
RX
RS232 Receive Data
NA
10
TX
RS232 Transfer Data
NA
11
A
RS485 anode
Reserved RS232 DTR
12
B
RS485 cathode
Reserved RS232 DSR
2) Connect Power Cable and Console Cable
The interface of TD210 is industrial terminal block, we suggest you use 28-16AWG power
cable and console cable.
Definition of power cable and console cable in this package are as below