Name of
parameter
ID at
configuration
Grade of
parameter
Parameter purpose
Measurement
unit
Default value
Factor Q
0951
4 byte
Q coefficient for Kalman
filter
c.u.
1000000
Factor H
0952
4 byte
H coefficient for Kalman
filter
c.u.
1000000
Factor Rs
0953
4 byte
R coefficient for Kalman
filter at motion absence
c.u.
20000000
Factor Rm
0954
4 byte
R coefficient for Kalman
filter at motion
c.u.
400000000
Ain1Per
0959
1 byte
Coefficient of median
filtering for analog input
No. 1 (from 1 to 256)
c.u.
19
Ain2Per
0980
1 byte
Coefficient of median
filtering for analog input
No. 2 (from 1 to 256)
c.u.
19
CanLog
program_num
0406
2 byte
Set program number of the
CAN LOG
-
0
canLogTM
0407
2 byte
CAN LOG polling period
sec.
5
RS232 Ena
5007
1 byte
Configuration of RS-232
mode:
(0 – off;
1 – CAN-LOG v1;
2 – RS-232 DUT;
3 – CAN-LOG v4
5 – CUB TPMS)
c.u.
0
dh1MedSize
4017
1 byte
Median filtering depth for
dHigh1F (from 1 to 256)
c.u.
30
AutoSetIO_Ena
0408
1 byte
Autosetting of CAN LOG
I/O elements
0 – disabled
1 - enabled
c.u.