Sample of setting:
At approaching RFID-card the device transfers its number (ID 157
at the transmission) to the server – 8597874069. Then we convert this
number into the HEX and get 200792595.
Further record the card number into the memory of the device from
the high-order byte to the low-order byte. The command will be as
follows:
setparam 0920 9525790002;
Configuring the device for working with fuel level
sensors by RS-485
“BI-530P TREK” tracking device enables work with fuel level
sensors via RS-485. Up to four fuel level sensors can be connected in
total.
To work with fuel level sensors, enable in the device settings the
corresponding I/O element (see
). In this case the fuel level
sensors shall be preset. Information on configuration of fuel level sensors
can be found in sensor relevant documentation.
The tracking device is able to transmit unprocessed (“raw”) data
from level sensors, as well as data processed by Kalman software filter.
Filtered and unfiltered values are passed by different I/O elements
In addition, if fuel level sensors are equipped with a built-in
temperature
sensor,
it
is
possible
to
obtain
these
data
and transfer them to the server (see
Setting the device for temperature sensors
The tracking device “BI-530P TREK” is able to work with
temperature sensors DS18B20. There can be connected up to five
temperature sensors.
To work with the temperature sensors turn on polling mode (ID
) in the device settings.
At detection of temperature sensors the device polls them and
obtains the current temperature values. When setting up the
corresponding I/O elements (
), the sensor values can be
transferred to the monitoring server.
For correct detection of temperature sensors, they must be properly
configured: each temperature sensor shall get a code number. Numbering
of sensors includes recording of special sequence of numbers to the
configuration registers. Necessary values are specified in Table 6.