20
www.bitrek.com.ua
[email protected]
+380 44 507 02 07
5 – Moni leaving the range.
When there is generated the event after leaving the range, the
actual value of the sensor starts to be transmitted to the server in
the monitoring mode.
6 – Moni returning/leaving to/of the range.
When one of the events is generated, the actual value of the sensor
starts to be transmitted to the server.
7 – Change of the input value to a predetermined value.
Changing of the input value to the predetermined value in either
direction will cause the event generation. The value is recorded to
the parameter “Upper limit”.
8 – Monitoring + change of the input value to a predetermined
value.
When the event is generated, the actual value of the sensor starts
to be transmitted to the server.
Parameter 5 – Averaging constant.
It is time required for I/O to be in a certain state in order to
generate an event. It is measured in milliseconds (X*50 ms, i.e., while
setting 10, the constant will be equal to 10*50=500 ms).
List of all I/O components of the device, available for configuration,
Notifications
Device can be configured to perform an outgoing voice call at
occurrence of certain conditions. Such a condition is a triggering of
predetermined I/O element. Voice calls shall be enabled in the general
settings of the device. I/O element shall be enabled, configured for one
of the events (entry to the range, exit out of the range, entry/exit in/out
of the range), its ID shall be defined as a trigger of outgoing call; Phone0
authorized phone number shall be defined.
An additional condition includes finding of the device in the
coverage area of GSM-operator and sufficient funds in the account. At the
absence of coverage the pursuant outgoing call will be postponed until
the moment when the device gets into the coverage area. The device
performs one attempt to make a voice call, per each trigger.
Setting to configure alerts are provided in the “Security” section in
Appendix 1. Authorized phone number Phone0 is recorded in the
parameter ID 0261.
In addition to a voice call, the device can send SMS to the
authorized phone number when the events occur. ID of I/O element,
which is used to send SMS, shall be defined as a trigger for outgoing SMS
messages. In addition to the SMS message you can add customized text,
where the text length shall not exceed 30 characters in the Latin
alphabet.