47
www.bitrek.eu
[email protected]
+372 880 78 78
No.
Name of
parameter
ID at
transmission
ID at configuration
Purpose
47
FrqVal
25
0830/0831/0832/0833/0834/0835
Frequency value of dl_Low 1 discrete
input
48
fuelCounter
1
136
0180/0181/0182/0183/0184/0185
dl_Low 1 pulse counter
49
HDOP
122
0800/0801/0802/0803/0804/0805
Reduced accuracy in the horizontal
plane
50
EKEY
105
0620/0621/0622/0623/0624/0625
Value of the identifier key
51
RFID Ekey
157
3800/3801/3802/3803/3804/3805
ID of approached RFID-card
52
iMCC
mcc
4010/4011/4012/4013/4014/4015
Positioning by base stations*
53
iMNC
mnc
4020/4021/4022/4023/4024/4025
Positioning by base stations*
54
iLAC
lac
4030/4031/4032/4033/4034/4035
Positioning by base stations*
55
iCellID
cell_id
4040/4041/4042/4043/4044/4045
Positioning by base stations*
56
Rx_level
rx_level
4050/4051/4052/4053/4054/4055
Positioning by base stations*
57
Socket_stat
139
5030/5031/5032/5033/5034/5035
Status of server connection socket
58
rebootCnt
46
5010/5011/5012/5013/5014/5015
Device reboot counter
59
FuelCounter
2
137
0190/0191/0192/0193/0194/0195
dl_Low 2 pulse counter
60
Can_stat
218
5510/5511/5512/5513/5514/5515
CAN BUS connection status
61
iButton
78
0400/0401/0402/0403/0404/0405
iButton key value
62
CAN_1
90
3600/3601/3602/3603/3604/3605 Activation of I/O-element No. 1 for CAN
63
CAN_2
91
3610/3611/3612/3613/3614/3615 Activation of I/O-element No. 2 for CAN
64
CAN_3
92
3620/3621/3622/3623/3624/3625 Activation of I/O-element No. 3 for CAN
65
CAN_4
93
3630/3631/3632/3633/3634/3635 Activation of I/O-element No. 4 for CAN
66
CAN_5
94
3640/3641/3642/3643/3644/3645 Activation of I/O-element No. 5 for CAN
67
CAN_6
95
3650/3651/3652/3653/3654/3655 Activation of I/O-element No. 6 for CAN
68
CAN_7
96
3660/3661/3662/3663/3664/3665 Activation of I/O-element No. 7 for CAN