INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Bisolid GP xx_B hc> . OM-BSGPHCV02/07/2017/EN
22
5.10.2 IGNITION SETTINGS
Table 7. Parameters in pellet burner ignition settings
5.10.3 SETTINGS IN BURN MODE
Table 8. Parameters of pellet burner settings in burn mode
NAME
DESIGNATION
LIMMITS
FACTORY
SETTING
Time for loading
Load
2 – 480 s
90 s
Blowing
Blowing
0 – 10 m
2 m
Time for the emergence of
flame
Fire time
1 – 15 m
8 m
Preheating
Preheat
0 – 180 s
100 s
Fresh air fan
Fan1
20 – 100 %
48 %
Flue gases fan
Fan2
20 – 100 %
100 %
Time for fuel heated
Inflame
60 – 600 s
120 s
NAME
DESIGNATION
LIMMITS
FACTORY
SETTING
Time for loading
Load
1 – 240 s
2 – 8 s
Time for burning
Pause
1 – 240 s
14 – 14 s
Fresh air fan
Fan1
20 – 100 %
48 – 100 %
Flue gases fan
Fan2
20 – 100 %
48 – 100 %
Ignition
*Load
90 s
Blowing
2m
Fire time
8 m
Preheat
100 s
Ignition
*Fan1
48 %
Fan 2
100 %
Inflame
120 s
EXIT
Min<Burn>Max
*Load
2 - 8s
Pause
14 - 14s
Fan1
48 - 100%
Fan2
48 - 100%
EXIT