background image

INSTALLATION, OPERATION AND MAINTENANCE MANUAL 

 

Bisolid GP xx_B hc>                              .                                      OM-BSGPHCV02/07/2017/EN 

3

 

1. 

IMPORTANT  INFORMATION  ABOUT  THE  PELLET 

BURNER OPERATION 

 

Dear Bisolid GP xx_B hc> pellet burner owners, 
 
We  would  like  to  congratulate  you  for  your  new  pellet  burner.  By  purchasing  this  quality 
product  from  the  manufacturer  you  have  chosen  a  system  that  ensures  higher  comfort  level 
and  optimized  fuel  consumption  in  environmentally  protecting  and  natural  resource  saving 
way. Your pellet burner is manufactured under strict ISO 9001 standards. 
 
On  the  next  pages  we  have  introduced  specific  information  and  important  advices  about  the 
system operation, its functions and methods of maintenance. Please pay special attention to 
this manual. Good knowledge of this document content will give you the pleasure of long-term 
and trouble-free operation of the pellet burner. 

 

 

1.1. 

SAFETY INSTRUCTIONS

 

 

The wood pellet burner from series Bisolid GP xx_B hc> and its accessories correspond to all 
applicable directions for safety techniques. Your wood pellet burner and all of its accessories 
operate  under  variable  electricity  230  VAC.  Improper  electrical  installation  or  repair  may 
endanger  user’s  life  from  electrical  shock.  Installation  works  must  be  performed  only  by 
qualified technicians. 
 
This manual is intended for authorized service specialists only. It is important to know that:  

  Works  on  the  heating  installation  should  be  performed  only  by  technicians  who  had 

acquired such rights by law. 

  Works on the electrical installation should be performed by qualified electricians only. 
  Initial  operation  start  up  including  installation  visual  checks,  adjustments  and  starting 

must be performed by the manufacturer authorized personal.  

 

Legal provisions 

While operating with the appliance please observe: 

  Legal provisions for safety techniques. 
  Legal provisions for environment protection. 
  Provisions for proper installation. 
  Applicable provisions of the European community. 

 

Safety instructions 

 

Danger 
Please observe these safety instructions in order to prevent the people from 
risks and harms, as well as damage to properties and environment. 

 
Safety instructions explanation. 
Please pay attention to the following symbols in this manual:  

Summary of Contents for GP 20_B18 hc

Page 1: ...ATION OPERATION AND MAINTENANCE MANUAL Bisolid GP xx_B hc 20 July 2017 OM BSGPHCV02 07 2017 EN MANUAL FOR INSTALLATION OPERATION AND MAINTENANCE OF PELLET BURNER SERIES BISOLID GP XX B HC http www bis...

Page 2: ...HEATING WATER ASSIGNMENT B SET 15 5 6 2 DETERMINATION OF THE HEATING WATER ASSIGNMENT ON OUTSIDE TEMPERATURE THROUGH SENSOR PT1000 15 5 6 3 DETERMINATION OF THE HEATING WATER ASSIGNMENT ON ROOM TEMPER...

Page 3: ...ty techniques Your wood pellet burner and all of its accessories operate under variable electricity 230 VAC Improper electrical installation or repair may endanger user s life from electrical shock In...

Page 4: ...provided by the manufacturer After carefully reading of the installation and operation manual you will acquire all necessary information about design controls and safety operation of the pellet burner...

Page 5: ...s designated to utilize wood pellets according to standard EN ISO 17225 2 2014 class A1 and its corresponding quality characteristics The fuel and the air are mixed in the burner by a precisely contro...

Page 6: ...Table 1 Table 1 Standard for wood pellets EN ISO 17225 2 2014 Wood pellets must be stored in dry premises so they can be transported without problems and also in order to achieve trouble free operatio...

Page 7: ...rmostat final blow In the optimization mode at the operation with the room thermostat is carried optimized modulation based on the thermal characteristics of the site The pellet burner is equipped wit...

Page 8: ...ung 13 Thermal switch 14 Isolation 15 Fire grate 16 Igniter 17 Combustion chamber 18 Combustion chamber cover 1 5 PELLET BURNER OVERALL DIMENSIONS The overall dimensions of pellet burner series Bisoli...

Page 9: ...d pellets Wood pellets category according to standard EN ISO 17225 2 2014 A1 Nominal heating output kW 18 25 32 Heating output range performed by authorized servicing technician kW 5 18 7 25 10 32 Pel...

Page 10: ...cing organization authorized by the manufacturer Every incompetent intervention might damage the pellet burner and possibly the accompanying equipment The servicing technician initializing the pellet...

Page 11: ...necessary also to observe the additional requirements as most important of them those that should not be missed are presented in the relevant regulation documents In addition to the above mentioned do...

Page 12: ...eration manual The surface of the pellet burner should be cleaned only with standard inflammable cleaners Positioning of objects made of flammable materials over or near the pellet burner at shorter t...

Page 13: ...te and manage the pellet burner and also to fill in the exact start of operation date in the warranty card of the product 4 2 JOINT OPERATION OF PELLET BURNER AND SOLID FUEL BOILER The pellet burner s...

Page 14: ...ply off the burner goes through stop procedure 5 3 STARTING THE PELLET BURNER When missing stop signal or in case of emergency situation and there is difference between the adjusted and the measured t...

Page 15: ...e current status See section SMS commands 5 6 METHODS FOR FORMING THE DESIRED TEMPERATURE 5 6 1 MANUAL DETERMINATION OF THE HEATING WATER ASSIGNMENT b set In this case the assignment is independent of...

Page 16: ...eads to a better control of the hot water It can choose from 0 to 60 min in increments of 5 minutes See section User settings When there are switches on and off from the room regulator and it operates...

Page 17: ...rner stops Circulations pump blocking protection drives rotates the pump for 5 minutes in case it has not been operating for at least 24 hours The minimum and the maximum assignment of the heating wat...

Page 18: ...manual is presented information only for the users The information for servicing specialists is presented separately The controller of the pellet burner is swithcing on and off by pressing and holding...

Page 19: ...TTINGS Table 3 Parameters of pellet burner user s settings 5 9 2 WEEKLY TIMER NAME DESIGNATION LIMMITS FACTORY SETTING Assignment for Water temperature manual Room temperature Room thermostat optimisa...

Page 20: ...NFORMATION ON ALARM MESSAGES The presence of an alarm message on the pellet burner is indicated by an icon Table 5 Information on alarm messages normal condition Err alarm message NAME DESIGNATION LIM...

Page 21: ...5 10 1 COMMON SETTINGS Table 6 Parameters of pellet burner common settings NAME DESIGNATION LIMMITS FACTORY SETTING Water limmits Tb lim 5 90 C 15 80 C Zone regulation Zone reg 5 30 C 10 C Type of con...

Page 22: ...10 m 2 m Time for the emergence of flame Fire time 1 15 m 8 m Preheating Preheat 0 180 s 100 s Fresh air fan Fan1 20 100 48 Flue gases fan Fan2 20 100 100 Time for fuel heated Inflame 60 600 s 120 s...

Page 23: ...as a button ON OFF as in switch on condition is executed the set weekly program NAME DESIGNATION LIMMITS FACTORY SETTING Time for afterburning Burn out 0 15 m 8 m Time for cleaninhg Clean on 0 24 h 6...

Page 24: ...TION CHARACTERISTIC Supply voltage 230V 50Hz Ignition element output 230V 0 3kW Circulations pump output 230V 0 35kW Fans ouput 3 pices 230V 0 25kW Fuel transport auger output 230V 0 25kW Cleaner supp...

Page 25: ...livered fully assembled and functionally tested The main pellet burner accessories are Installation and operation manual 1 pc Warranty card 1 pc Main module with combustion chamber 1 pc Isolation 1 pc...

Page 26: ...OPERATION AND MAINTENANCE MANUAL Bisolid GP xx_B hc OM BSGPHCV02 07 2017 EN 26 Figure 5 Dscription of actions in manually cleaning of the burner Figure 6 Dscription of actions in manually cleaning of...

Page 27: ...weekly thermostat When a device does not operate and is in standby mode due to the achieved temperature When the pellet burner is switch off When a device is switched off by the user it is necessary...

Page 28: ...r series Bisolid GP xx_B hc see Figure 7 is as follows 1 Pull the handle 1 back Unscrew and remove the handle 1 and screw 3 Push the rod all the way forward 2 and remove the fire gtare from the burner...

Page 29: ...e operation and installation manual The manufacturer is not responsible for failures or damages caused by unqualified installation The pellet burner series Bisolid GP xx_B hc must be connected to the...

Page 30: ...sition has to be considered so it can provide its reliable operation easy cleaning handling and servicing Correct positioning during the pellet burner installation guarantees reliable and efficient pa...

Page 31: ...The pellet burners for expedition are offered by the manufacturer in carton packages and are secured against moving The pellet burners can not be transported in position different from their base norm...

Page 32: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL Bisolid GP xx_B hc OM BSGPHCV02 07 2017 EN 32 7 PELLET BURNER WIRING DIAGRAM Figure 7 Wiring diagram of the pellet burner...

Page 33: ...cessary to change the pellets as possibly their water content is higher than the normal needed for the burner operation The fuel ignition is accompanied by untypical noises Insufficient chimney draugh...

Page 34: ...ty for replacement then change the fuses with the same corresponding parameters Warning the fuses are fast reacting The flame from the burning process is dim and the chimney smokes much Wood pellets w...

Page 35: ...ion mode over its nominal heating output Decrease the burner heating output by changing its heating output level Failure showed on the controller display Problem in the burner operation It is possible...

Page 36: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL Bisolid GP xx_B hc OM BSGPHCV02 07 2017 EN 36 Supplier Address City Street Tel Fax http Reserved rights for technical changes...

Reviews: