INSTALLATION, OPERATION AND MAINTENANCE MANUAL
BiSolid Comfort OM-BSCV00/08/2012/EN
36
7.10. FLUE OUTLET PIPELINE INSTALLATION
Figure 17 presents the correct connecting of the boiler flue pipeline to the chimney, by
additional pipe connection. Please observe the following rules when installing the flue
pipelines to the chimney:
Install the flue pipelines (pipe connection) to the chimney by checking the cleaning
manhole.
Fix the pipeline to the boiler flue outlet.
Install the flue gasses pipe to the chimney, by using the shortest track, without using
excessive number of bends. Avoid undesirable coupling sections, especially with 90 °
connection angle.
Fix the pipelines reliably by using enough number of supports (especially for long flue
pipelines).
The flue pipeline (pipe connection) must be installed carefully in order not to loosen,
because it is fixed only to the chimney inlet.
Use parts and components for connecting the boiler flue outlet to the chimney that are
made only from inflammable materials.