Operating Manual
36
after up steps, if the spindle motor would not start, please check the
undercurrent rely and oil pump control circuit and spindle motor control
circuit.
NOTE: There is a micro switch fixed on the inside of Wheel guard, if
the door have not been closed, the spindle motor could not start.
7. Start coolant pump
Turn the SA7 to
position, the coolant pump start, open the valve
located on the right side of the wheel guard, the coolant will flow out. Turn
the SA7 to “stop position, the coolant pump would power off. (the dust
collector is optional equipment, if the machine is special equipped with dust
collector, turn SA7 to
position, the dust collector is start)
8. Electro magnetic chuck operating
Turn SA5 to
“
magnetized” position
, the chuck on working(the HL3
alarm lamp will light); turn the SA5 to “ demagnetized
” position, the
chuck demagnetized; turn SA5 to “ stop”
position, the chuck would
work.
NOTE: if the chuck suction force is low, may be caused by: VC is
broken which located in the Rectifier circuit.
If the chuck have no force, may be caused by:
1)
the Undercurrent rely is broken
2)
electric circuit is take off
3)
the chuck is burned.
Summary of Contents for WSG1640AHD
Page 1: ...WSG1640AHD SURFACE GRINDING MACHINE OPERATING MANUAL ...
Page 66: ...Operating Manual 58 Circuit diagram ...
Page 67: ...Operating Manual 59 ...
Page 68: ...Operating Manual 60 ...
Page 69: ...Operating Manual 61 ...
Page 70: ...Operating Manual 62 ...
Page 71: ...Operating Manual 63 ...
Page 72: ...Operating Manual 64 ...
Page 73: ...Operating Manual 65 ...
Page 74: ...Operating Manual 66 ...
Page 79: ...Operating Manual 71 Elevating structure ...