Loop detector DIN variant, mounting rail installation
LCD display
«Mode» button
«Data»-button
Terminals
Info LED
2
Mechanical mounting in the switch cabinet
3
Electrical connection
Terminal connection diagram loop detector
Translation of the original instructions
Safety instructions
1
General
These devices and their accessories may only be operated in compliance with the operating instructions (intended use)!
These devices and their accessories may only be commissioned by trained and qualified personnel.
These devices may only be operated with the intended operating voltages and parameters.
If malfunctions occur that cannot be rectified, shut down the device and send it in for repair.
These devices are only allowed to be repaired by the manufacturer. Tampering and alterations are not permitted. This will invalidate all guarantee and
warranty claims.
The loop detector is mounted on a 35 mm mounting rail acc. to EN 50 022 in the switch cabinet.
The terminals are pluggable and coded.
A:
Supply
voltage
connection
B:
Loop connection
1-channel device
C:
Loop connection
2-channel device
E:
Relay connection
output 1
F:
Relay connection
output 2
AC
AC
A1
A2
14
11
12
no
nc
common
24
21
22
no
nc
common
L3
L4
L3
L4
L5
L6
1
2
The loop connection wiring to the loop detector must be twisted at least 20 times per meter.
Please wire the device in accordance with the terminal assignment. Make sure the terminals are assigned correctly.
1-loop device
Relay assignment:
Output connection
diagram:
Output 1
E
Output 2
F
2-loop device
Relay assignment:
Output connection
diagram:
Output 1+2
E, F
Output connection options (depending on the options ordered):
3.1
E
N
G
LI
S
H
General
Explanation of the LCD display
Explanation of the LED
Standard display
1-loop device
Standard display
2-loop device
Control button
Control button
1
1
2
Mode
Data
Sim1
Sim2
Mode
Data
Sim1
Sim2
1
2
Loop 2
Example:
Parameter «h»
set
Function
Example:
Time
function set
Loop 1
Info
Red + green:
Start-up phase
Green:
Operation
Red + green:
Configuration
Flashing green: Output 1 and/or
2 activated
Flashing red:
Error
Flashing
red + green:
Simulation
The settings of the loop detectors in this chapter are shown and explained for the 1-loop device. The settings for loop 2 of a 2-loop device should be made
using the corresponding method.
4
Value and parameter setting options
LCD display and controls
4.1
DI1-
Pro
V2
/
DI2-
Pro
V2
Loop detector for industrial doors
and gates, car parks and parking bollards
5