6.  Specifications  

The  unit  is  designed  for  operation  in  cold  rooms,  incubators  and  closed 

-condensing 

decreasing linearly to 50% relat

 

6.1. 

Temperature specifications 

 

Setting range  ........................................................................ 

 

 

Control range ...................................................... 

 

 

Setting resolution  .................................................................................. 

 

 

Stability ................................................................................................ 

 

 

Accuracy .............................................................................................. 

 

 

 ........................................................................... 

 

 

 

 ....................................... 12 min 

 

Temperature calibration option* 

 

Calibration coefficient range* ...................................... 

 

6.2. 

General specifications 

 

Speed setting range  .............................................................. 250 - 1200 rpm 

 

Speed setting resolution  ..................................................................... 10 rpm 

 

Orbit ....................................................................................................... 2 mm 

 

Display .................................................................................. 16x2 signs, LCD 

 

Digital time setting range ........................................ 1 min  96 hrs / non-stop 

 

Max. continuous operation time  ....................................................... 96 hours 

(recommended interval between operation sessions not less than 8 hours) 

 

Time setting resolution .......................................................................... 1 min 

 

Max. height of microtest plate  ............................................................. 18 mm 

 

External power supply ..........  input AC 100-240 V 50/60 Hz, output DC 12 V 

 

PST-60HL 

PST-60HL-4 

Current/power consumption 

12 V DC, 3.3 A / 40 W 

12 V DC, 4.15 A / 50 W 

Number of microplates  

Platform dimensions  

250 x 150 mm  

210 x 290 mm 

Dimensions 

270x260x125 mm 

380x390x140 mm 

Weight** 

6.1 kg 

8.8 kg 

 

Replacement parts 

Description 

Catalogue number 

Rubber belt 

122x0.6x6 mm 

BS-000000-S18 

 
Biosan is committed to a continuous program of improvement and reserves 

the right to alter design and specifications of the equipment without additional notice. 

 

Only for models of version V.6AW (PST-60HL) and V.4AW (PST-60HL-4). 

** 

 

DOMINIQUE DUTSCHER SAS

Summary of Contents for PST-60HL

Page 1: ...D O M I N I Q U E D U T S C H E R S A S ...

Page 2: ...2 D O M I N I Q U E D U T S C H E R S A S ...

Page 3: ...Precautions 4 2 General information 6 3 Getting started 7 4 Operation 8 5 Calibration 10 6 Specifications 12 7 Maintenance 13 8 Warranty and Claims 14 9 Declaration of Conformity 15 D O M I N I Q U E D U T S C H E R S A S ...

Page 4: ...fications to the design of the unit ELECTRICAL SAFETY Connect only to the external power supply unit with voltage corresponding to that on the serial number label Use only the external power supply unit provided with this product Ensure that the switch and external power supply are easily accessible during use Do not plug the unit into an ungrounded power socket and do not use an ungrounded extens...

Page 5: ...possible operation of the unit in specific atmospheres Do not operate the unit if it is faulty or has been installed incorrectly Do not fill in the microplates after they have been inserted in the unit Do not use outside laboratory rooms Do not check the temperature by touch Use a thermometer BIOLOGICAL SAFETY hazardous material is spilled on or penetrates into the equipment D O M I N I Q U E D U ...

Page 6: ... 60HL PST 60HL 4 Plate Shaker Thermostat provides soft or intensive sample shaking rotation speed regulation stabilization and indication even shaking amplitude throughout Shaker Thermostat platform required operation time setting and indication automatic stopping of the platform movement after the set time expires current operation time indication setting and indication of the required temperatur...

Page 7: ...ST 60HL PST 60HL 4 Plate Shaker Thermostat 1 pce spare rubber belt 2 pcs external power supply 1 pce power cord 1 pce Operating manual Certificate 1 copy 3 3 Set up place the unit upon even horizontal non flammable surface away from any flammable materials not less than 30 cm remove protective film from the display plug the external power supply unit into the socket at the rear side of the unit an...

Page 8: ...eadings in the upper line of the display Set while setting the necessary parameters Pressing the key for more than 3 s will increase the increment 4 3 1 Setting time TIME he required working time interval in hours and minutes increment 1 min 4 3 2 Setting speed RPM uired speed increment 10 RPM 4 3 3 Caution The platform heating can be turned off only by setting the set point It can be used in cold...

Page 9: ...s operation of the Thermo shaker timer indicator will start counting up the time interval in the lower line Actual until the RPM RUN STOP key is pressed again Please note The platform temperature will be constantly maintained in accordance with the set temperature This allows using the device again without pre heating 4 6 The timer can be reset during operation if required Press the TIME RUN STOP ...

Page 10: ...ig 1 6 as shown on Fig 2 1 to restore the factory settings Press the Run key fig 1 7 once to save the changes and exit the calibration mode Note Coefficient value changes are recommended after the unit has 5 4 1 Calibration procedure spectrocells placed into the block sockets 5 4 2 Fig 2 Control panel in calibration mode 5 4 3 After the unit reaches the set temperature when the set and current tem...

Page 11: ... correct temperature through all the operation range Note Coefficient value changes are recommended after the unit has 5 4 7 After finishing the calibration press the Run key fig 1 7 once to save the changes and exit the calibration mode 5 4 8 The display will show calibrated temperature as shown on fig 4 1 and the unit will continue thermal stabilization according to the previously set temperatur...

Page 12: ...n operation sessions not less than 8 hours Time setting resolution 1 min Max height of microtest plate 18 mm External power supply input AC 100 240 V 50 60 Hz output DC 12 V PST 60HL PST 60HL 4 Current power consumption 12 V DC 3 3 A 40 W 12 V DC 4 15 A 50 W Number of microplates 2 4 Platform dimensions 250 x 150 mm 210 x 290 mm Dimensions 270x260x125 mm 380x390x140 mm Weight 6 1 kg 8 8 kg Replace...

Page 13: ...ation time To replace the belt Disconnect the external power supply unit from the device Remove 4 fixation screws on the underside and remove the bottom plate Replace the rubber belt fig 5 Reassemble the device Fig 5 Rubber belt replacement 7 5 Error codes in case of a defect Following error codes are shown in the lower right corner of the display fig 1 accompanied by a sound signal every 8 s Pres...

Page 14: ...ranty 8 3 Warranty covers only the units transported in the original package 8 4 If any manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the local distributor address Please visit www biosan lv Technical support section to obtain the claim form 8 5 The following information will be required in the event that warranty or ...

Page 15: ...15 9 Declaration of Conformity Edition 4 6 01 April 2016 D O M I N I Q U E D U T S C H E R S A S ...

Page 16: ...D O M I N I Q U E D U T S C H E R S A S ...

Reviews: