Bioreba HOMEX 7 User Manual Download Page 3

HOMEX 7 – User Guide

 

1. Foreword

Thank you for purchasing the HOMEX 7, a semi-automated homogenizing device for the grinding of plant samples 
such as leaves, wood, roots, seeds, and tubers.

The HOMEX 7 is ideal for high throughput applications and allows you to load up to 5 extraction bags. This user 
guide describes the HOMEX 7 functionalities, safety and operation instructions. Please read this user guide carefully 
before using the HOMEX 7 for the first time and keep it for later reference and troubleshooting.

1.1. Content check

Please check the packing list (see chapter 7) when you first open the HOMEX 7 packaging. If the instrument is da-
maged or items are missing, please contact us immediately.

 

 

3

2. Safety warnings and guidelines

Read this user guide before operating the instrument for the first time and follow the safe operating procedures 
described below.

2.1. Safe Operating Procedures

The operation, maintenance and repair of the instrument should comply with the basic usage guidelines and the 
warnings listed below. Failure to comply with these guidelines may result in injury, affect the life span of the instru-
ment and may result in the invalidation of the warranty.

• 

Do not carry the HOMEX 7 by yourself. Never carry 

the HOMEX 7 holding it by the rack, the handle, or 

by any other external part. For short distances at 

least 2 people should carry the instrument holding it 

by the base plate.

• 

In case you need to ship the HOMEX 7, always use 

the original packaging.

• 

Do not drop the HOMEX 7.

• 

This device has been designed for indoor and non-

extreme temperature conditions use only.

• 

In case the device is malfunctioning or is damaged, 

the operator should not try to repair it. This will 

result in the loss of warranty and may cause serious 

injury. If the device is not working properly or is de-

fect, please contact the manufacturer immediately.

• 

Before connecting the device to a power socket, 

make sure the voltage stated on the rating label 

of the product corresponds to the voltage in your 

power socket. 

• 

Ensure that the power plug does not come into 

contact with water or moisture.

• 

Do not disconnect the device from the power 

socket by pulling on the power cord. This could 

damage the power cord or the power socket. Dis-

connect the cord from the power socket by gently 

pulling the plug of the power cord.

• 

Always place the instrument on a horizontal, stable 

and even surface. The surface must be resistant to 

heat and fluids.

• 

Any liquid in contact with the electronic parts of the 

device may cause damage and provide a significant 

hazard.

• 

The instrument should be placed in a dry, cool and 

dust-free environment with no exposure to direct 

sunlight. The instrument should be used only in a 

well-ventilated environment, with no corrosive gas 

or strong disturbing magnetic field, away from cen-

tral heating and other heat sources. 

• 

Switch off the instrument when you finished to work. 

• 

Pull out the connector plug when you don’t use the 

device for a long period of time. Clean the instru-

ment and cover it with a cloth to protect from dust.

       Do not:

• 

Use the instrument for anything other than its 

intended use.

• 

Use a different power supply unit than the 

one supplied (Art. No. 400028).

• 

Use the instrument if the cable to the power 

supply unit is damaged.

• 

Pull the connector plug and contact the vendor in 

the case:

• 

The instrument is drenched or fire burned.

• 

The instrument produces abnormal noises or 

smells. 

• 

The instrument dropped.

• 

The instrument does not function properly.

Yo

ur P

ar

tn

er i

n A

g

ro

-D

ia

g

no

st

ic

s

Summary of Contents for HOMEX 7

Page 1: ...HOMEX 7 USER GUIDE Your Partner in Agro Diagnostics...

Page 2: ...rating Procedures 3 3 Maintenance of the instrument 4 4 Introduction 4 Table 1 Specifications 5 5 Operation guide 5 5 1 Replacing the rack 6 5 2 Removing the ball bearing head 6 6 Frequently Asked Que...

Page 3: ...rator should not try to repair it This will result in the loss of warranty and may cause serious injury If the device is not working properly or is de fect please contact the manufacturer immediately...

Page 4: ...an instrument for the homogenization of plant tissues Plant material such as roots leaves and wood slices is inserted into a BIOREBA extraction bag with the appropriate amount of buffer Up to 5 BIORE...

Page 5: ...amples or watch a video tutorial by scanning following QR code Plug the power supply unit into a socket and connect the HOMEX 7 with the power supply cable at the front left side of the instrument Pre...

Page 6: ...following QR code Fig 6 5 2 Removing the ball bearing head In order to replace or clean the ball bearing head you first need to remove the 4 screws on the side using the pro vided 2 mm allen key and...

Page 7: ...Pull the clamping screws tightly Fig 3 Extraction bag breaks during homogenization Too much pressure has been ap plied to the sample Sample may be too hard edgy e g wood samples hard roots or big see...

Page 8: ...tion bags Universal U form Art No 440100 4 25 rack version 1x HOMEX 7 incl Rack 4 25 Art No 4000074 100x BIOREBA extraction bags Universal Long Art No 470100 Both versions also contain 1x Power supply...

Page 9: ...HOMEX 7 USER GUIDE Your Partner in Agro Diagnostics...

Page 10: ...chere Betriebsabl ufe 3 3 Wartung des Instruments 4 4 Einleitung 4 Table 1 Leistungsbeschreibung 5 5 Bedienungsanleitung 5 5 1 Austausch des Racks 6 5 2 Entfernen des Kugellagerkopfes 6 6 H ufig geste...

Page 11: ...f r den Einsatz in Innenr u men und bei nicht extremen Temperaturen entwi ckelt Falls das Ger t nicht richtig funktioniert oder be sch digt ist sollte die Reparatur nicht durch den Anwender erfolgen...

Page 12: ...ersal oder Universal U form k nnen in das Standard Rack eingesetzt werden F r gr ere Proben k nnen bis zu 4 BIOREBA Extraktionsbeutel Universal Long in ein 4 25 Rack ein gesetzt werden Das homogenisie...

Page 13: ...indem Sie den folgenden QR Code scannen Stecken Sie das Netzteil in eine Steckdose und verbinden Sie den HOMEX 7 mit dem Netzkabel an der linken Vorderseite des Ger ts Bereiten Sie die Proben mit den...

Page 14: ...QR Code scannen Abb 6 5 2 Entfernen des Kugellagerkopfes Um den Kugellagerkopf zu ersetzen oder zu reinigen m ssen Sie zun chst die 4 Schrauben an der Seite mit dem mitgelieferten 2 mm Inbusschl ssel...

Page 15: ...ina nicht Ziehen Sie die Klemmschrauben fest Abb 3 Der Extraktionsbeutel rei t w hrend der Homogenisie rung Es wurde zu viel Druck auf die Probe ausge bt Die Probe ist zu hart kantig z B Holzproben ha...

Page 16: ...tel Universal U form Art No 440100 4 25 Rack Version 1 x HOMEX 7 inkl Rack 4 25 Art No 4000074 100 x BIOREBA Extraktionsbeutel Universal Long Art No 470100 Alle Versionen enthalten zudem 1 x Netzteil...

Page 17: ...HOMEX 7 USER GUIDE Your Partner in Agro Diagnostics...

Page 18: ...t 3 2 1 Proc dures d utilisation s res 3 3 Entretien de l instrument 4 4 Introduction 4 Table 1 Sp cifications 5 5 Guide d utilisation 5 5 1 Changement du rack 6 5 2 Changement de la t te de broyage 6...

Page 19: ...u pour une utilisation l in t rieur et dans des conditions de temp rature non extr mes En cas de dysfonctionnement de l appareil ou d en dommagement l op rateur ne doit pas essayer de le r parer Cela...

Page 20: ...OREBA Universal Long peuvent tre ins r s dans un rack 4 25 Le tissu homog n is est filtr par la couche interm diaire synth tique des sachets BIOREBA et peut ensuite tre facilement utilis pour des appl...

Page 21: ...chantillons ou suivez une vid o didactique en scannant le code QR suivant Branchez le bloc d alimentation dans une prise et connectez le HOMEX 7 avec le c ble d alimen tation situ l avant gauche de l...

Page 22: ...ant le code QR suivant Fig 6 5 2 Changement de la t te de broyage Pour remplacer ou nettoyer la t te de broyage vous devez d abord retirer les 4 vis sur le c t l aide de la cl Allen de 2 mm fournie pu...

Page 23: ...sa tion Trop de pression a t appliqu e sur l chantillon L chantillon est trop dur ou tran chant par exemple des chan tillons de bois racines dures ou grosses graines vitez d appliquer trop de pression...

Page 24: ...Universal U form Art No 440100 Version Rack 4 25 1 x HOMEX 7 quipp avec Rack 4 25 Art No 4000074 100 x sachets d extraction BIOREBA Universal Long Art No 470100 Toutes les versions contiennent 1 x Blo...

Page 25: ...inach Switzerland Phone 41 61 712 11 25 Fax 41 61 712 11 17 Your Partner in Agro Diagnostics admin bioreba ch www bioreba com www bioreba com Your Partner in Agro Diagnostics www bioreba com Version 1...