31
Flue Gases Temperature Sensor Overheating
–
temperature of flue gases achieved the value set in
item 4.1 «Safety». Controller moves to the
emergency flameout mode.
Hot Water Supply Temperature Sensor Failure
– replace the hot water supply temperature sensor.
The boiler continues working, switches to house
heating priority. Hot water supply pump does not
start up.
Boiler Temperature Sensor Failure
– replace
the boiler temperature sensor.
Flue Gases Temperature Sensor
Failure
–
replace the flue gases temperature sensor. The boiler
moves to emergency mode, switches on Central
Heating pump and Hot Water Supply pump.
Basket
temperature
sensor
failure
–
temperature of pellet receiver achieved
the value set
in item 4.1 «Safety».
The boiler moves to STOP
mode, Central Heating pump and Hot Water Supply
pump switch on automatically.