background image

If  the  Spa Star  does  not  respond  to  the  Remote 

«

Control,  the  most  likely  cause  is  that  the  batteries 
need to be replaced.

However,  in  case  there  has  been  some  spike  or 
interference which has caused the Spa Star and the 

«

Remote Control to simply not be synced together, we 
suggest  that  you  first  follow  the  “Learning  a  New 
Remote Control” procedure below.

If the red LED on the Remote Control does not light 
when the button is pressed, then the batteries also 
need to be replaced.

REPLACEMENT PROCEDURE

1. Insert  your  finger  or  thumb  nail  into  the  seam 

where the two halves of the enclosure join. Gently 
prise the enclosure apart. Do not use a tool, which 
could damage the plastic.

2. Slide the two batteries out of the battery holder.

3. Slide two new CR2016 batteries into the battery 

holder. Both batteries must have the + side facing 
up. DO NOT MIX OLD AND NEW BATTERIES.

4. Press  the  two  halves  of  the  enclosure  back 

together. Ensure that the seam is even all the way 
around. 

5. Test the operation of the Remote Control.

If  the  Red  light  is  lighting  when  the  button  is 
pressed, but the Spa Star does not respond, then 

«

follow  the  “Learning  a  New  Remote  Control” 
procedure below. 

If the Red light does not light when the button is 
pressed, then the Remote Control maybe faulty. 
Contact Bionizer or your distributor if this is the 
case.

The Spa Star and Remote Control use a rolling code 

«

to ensure that other radio devices do not interfere 
with the unit. If the Remote Control is replaced at 
some  time,  then  it  is  necessary  to  follow  this 
procedure to sync the new Remote Control with your 
Spa Star  unit.

«

On  rare  occasions,  your  Spa Star    may  lose  sync 

«

with the Remote Control, so that it does not respond 
when you press the Remote Control button. If this 
happens,  follow  this  procedure  to  re-sync  your 
Remote  Control.  If  it  continues  to  not  respond, 
replace the batteries as per the procedure above. If 
this also fails, then replace the Remote Control.

 

REMOTE CONTROL LEARNING PROCEDURE

1. Switch the power to the Spa Star  OFF.

«

2. Press  AND  HOLD  the  One  Shot  Ionizing  button 

while switching the power to the Spa Star  back 

«

ON. 

3. The 7 LEDs will be showing a pattern where they 

go from Off to 60 around once per second.

4. Press the button on the Remote Control. The LEDs 

should go out immediately if the Spa Star   and 

«

the Remote Control synced OK. 

  If the LEDs continue the self-learning pattern, then 

there  is  a  fault.  Contact  Bionizer  or  your 
distributor.

REMOTE CONTROL

REPLACING THE REMOTE CONTROL BATTERIES

THE SPA STAR REMOTE CONTROL REQUIRES TWO CR2016 BATTERIES

«

LEARNING A NEW REMOTE CONTROL

IF THE SPA STAR REMOTE CONTROL IS REPLACED, IT MUST BE SYNCED TO THE UNIT

«

14

INSTRUCTION BOOK

Summary of Contents for Spa Star

Page 1: ...System Please read before you call us for advice Version 2 0 25 May 2016 www bioniser com au www bionizer com C h l o r i n e F r e e P o o l S y s t e m s TM Spa Star Ionizing Time Minutes Spa Star...

Page 2: ...ON 3 SPA STAR ILLUSTRATION 4 SAFETY INSTRUCTIONS 5 SPA STAR INSTALLATION 5 CONTROL BOX INSTALLATION 5 INSTALLING THE IONIZING AND OXIDIZING PODS 6 MAKING THE JOINER WHEN INSTALLING PODS END TO END 7 I...

Page 3: ...levelisgettinglow SimplyselecttheOneShotIonizingtime andtheSpa Stardoestherest Simple effectiveandchemicalfree As with all Bionizer products ensure that the pool water is correctly balancedat all tim...

Page 4: ...nd ring terminals Titanium Anode plates with black coating and spade terminals 7 LEDstoshowOne ShotIonizingtimesettingselection AlsoshowsIonizingtimeremainingin10minuteintervals WhenIonizingtimeisshow...

Page 5: ...low you to see the Spa Star LED readout easily Fix the control box in position using screws at each corner of the box Ensure that the Spa Star is positioned near enough to a power outlet and to the Io...

Page 6: ...scanbefittedhorizontallyorvertically so they can be mounted anywhere installation is convenientandeasy If you are installing a pH BOSS the fittings MUST beinstalledinthisorder 1 pH BOSS ProbeandInject...

Page 7: ...ntothem Illustrationoftheadaptorwithpipegluedin Will both Pods be fitted end to end on one straight section of pipe or will they be installed ontotwoseparatesectionsofpipe If the two Pods can be fitte...

Page 8: ...secure the four barrel union nuts Hand tighten only do not use atool Ensure that the Ionizing Pod is fitted before the OxidizingPodinthedirectionofwaterflow Fit the ring terminals to the bolts on eac...

Page 9: ...o place and secure the four barrel union nuts Hand tighten only do not use a tool Ensure that the Ionizing Pod is fitted before the OxidizingPodinthedirectionofwaterflow Fit the ring terminals to the...

Page 10: ...utton presses the Spa Star requires a 1 second pause between each time the Remote Control button is pressed After 3 seconds the Spa Star will beep save the newsetting andstarttheOneShotIonizingCycle T...

Page 11: ...various pool balance levels and re balancing the pool water according to the Snap Pool Balance table on the rear cover of this manual and also supplied as a chart with the Spa Star Feel free to take...

Page 12: ...of diluted pool acid We recommend to use a standard 10 Litre bucket Fill with around 4 Litres of water FIRST then add around 0 5 Litres of pool acid ALWAYS ADD ACID TO A LARGER VOLUME OF WATER NEVER...

Page 13: ...tandwithoutcorrosion Faulty connections can be repaired by persons with technical experience or can be returnedtoBionizerforrepair Unit does not power up Faulty AC DC poweradaptor Replacepoweradaptor...

Page 14: ...Remote Control maybe faulty Contact Bionizer or your distributor if this is the case The Spa Star and Remote Control use a rolling code to ensure that other radio devices do not interfere with the un...

Page 15: ...en thereiswaterflowthroughthereturn to poolpipeline afterthefilter Inthisway theundesirablecompounds will be oxidized as they are formed in the pool so they are not able to increase to a concentration...

Page 16: ...Weekly Monthly Monthly Monthly Quarterly Treatment Product Hydrochloric Acid 5mL 1 000L pH 0 1 0 2 FL OZ 5mL 250 Ga pH 0 1 Bionizer Program Settings Turn output Up or Dn Buffer Soda Bi Carb 20gm 1 000...

Reviews:

Related manuals for Spa Star