Maintenance
IMPORTANT! The boiler can be maintained by an adult only who has already familiarised with
its functions and the term of use.
The person who performs the maintenance of the boiler shall follow the
boiler’s user manual, set the desired heating water temperature, stop the boiler and control its
operation.
The person in charge of the maintenance of the boiler shall be familiarised with
boiler’s functions and the terms of use by the service employees when the boiler is installed and
ready for work.
During the performance of such works, the children are prohibited from being near the
boiler. It is strictly forbidden to disturb the operating mode of the boiler if the device can cause a risk to
the health and life of persons who perform the maintenance of boiler or other persons. The boiler can be
used up to the highest water temperature of 85 °C.
Maintenance of boiler
At least once every 14 days it is necessary to check the condition of heated water in the boiler and in the entire
heating system (to check if there is no leakage and lack of water). If the water content is not sufficient in the
heating system, it is necessary to fill it. After the end of the heating season, it is necessary to clean the boiler
thoroughly and to replace the damaged parts. The average duration of the glass fibre sealing rope usage is 0.5
years (subject to the frequency of opening of doors). If the sealing rope is pressed and is not suitable to be used
according to the purpose of use, it is possible to adjust the closing and hinges or to take out the rope from the
grooves of doors, to rotate by 90° and to reinsert to the groove of the doors. It is only a temporary solution,
therefore, it may be necessary to replace the sealing rope immediately.
At least twice a heating season, it is necessary to dismantle the ventilator and to clean the blade of
ventilator’s rotor.
After the end of the heating season, it is necessary to perform the general thorough cleaning
of the boiler. During the general cleaning, it is necessary to clean well the heat exchanger, burner, walls of the
boiler, box of ashes by removing all ashes, soot and other dirt. In case of performance of the general cleaning, it
is recommended to cover the inside of the boiler with anti-corrosive material. The content of soot and volatile
ashes depends on the quality of fuel and maintenance conditions. The soot and volatile ashes tend to
accumulated more if the boiler is of higher capacity than necessary or the boiler is used under the temperature
that is too low.
Replacement of door sealing rope
It is necessary to remove the sealing rope from the door notch and clean the notch. A new sealing rope is placed
to the cleaned notch. The start of the rope is inserted to the horizontal notch of the doors. The rope is inserted to
the notch of door perimeter manually or by gently hitting with a small hammer. The doors are then slightly
closed and the rope is pushed to the notch so that it could be easy to close the doors.