Selection of fuel
This option is used to select one of the following types of fuel: straw pellets 1, straw pellets 2 or wood pellets.
V.g)
Manual mode
The manual mode function is planned in the controller for more convenient operation of the device. Irrespective of
other devices, this function can be used to activate and deactivate each operated device. It is easy to check if the
device functions properly, i.e. burner, feeder, air blower (fan), CH pump, DHW pump, additional contact and valves
(valves can be opened or closed manually).
Furthermore, the user can regulate the speed of ventilator on the manual operation mode by using “
blow force
”
function.
V.h)
Weekly control
This function allows the user to program the weekly CH boiler operation schedule and to define the pre-set changes
of CH boiler and DHW temperature. The controller can be used to set three weekly control modes.
V.h.1)
Weekly control of CH boiler
Weekly control function allows the user to program the pre-set CH boiler temperature changes on specific hours and
days of the week.
In order to activate this function, please select Mode 1 or Mode 2. Detailed settings of each mode are available in the
auxiliary menu: “
Set mode 1” and “Set mode 2”.
Having selected the necessary mode, in the main screen you will see the operating temperature deviation value
(below the pre-set CH temperature, contrary than with the advance setting button), which shows to the user that this
function has been activated.
How to change the weekly control settings?
ST-560 controller allows the user to program the weekly control function on two modes: “MODE 1” – the user sets
temperature deviations for all days of the week individually; “MODE 2” – the user sets temperature deviations for all
business days (Monday - Friday) and for weekends (Saturday and Sunday) individually.
How to configure mode 1?
In order to configure mode 1, please select “
Set mode 1”
– the monitor shows the point of the specific days of the
week.
When the specific day of the week is selected, the screen shows the editing post - the upper row shows the current
deviation, the bottom row shows the time-period.
Please use and to change the time-period. In order to edit the value of deviation, use and .
In order to copy the parameter of the other time-period, please use .
When the temperature changes for the prepared specific day, please press “CONFIRM” icon – the screen will show
the screen allowing to copy the settings on other days.
For example:
Monday
Set: 3
00
, temp. -10
0
C (weekly control parameter – 10
0
C) setting: 4
00
,
temp. -10
0
C (weekly control parameter – 10
0
C) setting: 5
00
, temp. -10
0
C
(weekly control parameter – 10
0
C)
In this case, if the advance CH boiler setting temperature is 60
0
C, from 3
00
to 6
00
13