5.1 CLEANING AND MAINTAINANCE (staff responsible for maintainance)
EXHAUST SYSTEM – CHIMNEY
(Needs to be cleaned every six months or after two tons of pellets.)
Ensure that the furnace and the ashes have cooled down.
The wind-resistant exhaust system (chimney) needs to be inspected and cleaned each year. This is best done
right at the start of the season. It is best to consult an authorised service centre before cleaning these
elements. For spaces that need extra care when cleaning refer to figure 17.
INTERNAL FIREBOX
(once per year or after 1 ton of pellets)
Ensure that the furnace and the ashes have cooled down.
For correct cleaning with a vacuum cleaner:
Remove the back plate of the combustion chamber by unscrewing 4 screws. Remove the plate as shown under
5.0 (figures 14 and 15) and clean the accumulated ashes.
EXHAUST CHAMBER OF THE SMOKE FAN
(once per year or after one ton of pellets).
Ensure that the furnace and the ashes have cooled down.
Perform the cleaning of the interior chamber by first removing the lid on the bottom of the housing. Insert
vacuum cleaner and remove excess ashes in order to ensure proper furnace operation (figures 14 and 15).
GENERAL CLEANING AFTER SEASON
Ensure that the furnace and the ashes have cooled down – unplug from power source.
At the end of the season unplug the furnace from the power source. It is important to clean the furnace and
inspect it as shown above.
Ensure that the furnace and the ashes have cooled down.
The door seal may loosen after longer periods of usage. The seal attaches to the door with heat-resistant
silicone. Attach the back end of the heat-resistant sealing tape. This is very important to ensure proper door
sealing.