5.9 Flow chart
Fig. 11
Flow chart
Y1
5/2 directional valve stroke UP - DOWN
Y2
5/2 directional valve for clamping cylinder (CLAMP - RELEASE) and for
compressed-air motor (ON - OFF)
Y3
5/2 directional valve for wire cutter (ON - OFF)
Y4
5/2 directional valve for injector (ON - OFF)
Air-blast option
Air-blast through cable assembly (ON - OFF)
Ready
Home position of the cleaning station (stroke cylinder down, S1 activated)
Tab. 14
Explanations
Cleaning &
Injection
Position P1
Approach
Position P2
Approach
Output
Y2 = I
Waiting time
approx. 0.5 sec.
Output
Y1 = I
Waiting time
approx. 2 sec.
Output
Y1 = 0
Position P3
Approach
Output
Y4 = 1
No
Yes
Input
Ready = 1
Option
Air blast = 1
Input
Ready = 1
Position P4
Approach
Output
Y4 = 0
Position P3
Approach
Output
Y3 = I
Waiting time
approx. 0.5 sec.
Option
Air blast = 0
Output
Y3 = 0
Determine cause
and eliminate it
No
Yes
Determine cause
and eliminate it
Output
Y2 = 0
Waiting time
approx. 1 sec.
Position P5
Approach
Move out of
maintenance station